Determination of Cooling Parameters for a High-Speed, True-Scale, Metallic Turbine Vane

Author:

Polanka Marc D.1,Rutledge James L.2,Bogard David G.3,Anthony Richard J.4

Affiliation:

1. Department of Aeronautical Engineering, Air Force Institute of Technology, WPAFB, Dayton, OH 45433 e-mail:

2. Department of Aeronautical Engineering, Air Force Institute of Technology, WPAFB, Dayton, OH 45433

3. Department of Mechanical Engineering, University of Texas, Austin, TX 78415

4. Aerospace Systems Directorate, Air Force Research Laboratory, WPAFB, Dayton, OH 45433

Abstract

Facilities such as the Turbine Research Facility (TRF) at the Air Force Research Laboratory have been acquiring uncooled heat transfer measurements on full-scale metallic airfoils for several years. The addition of cooling flow to this type of facility has provided new capabilities and new challenges. Two primary challenges for cooled rotating hardware are that the true local film temperature is unknown, and cooled thin-walled metallic airfoils prohibit semi-infinite heat conduction calculation. Extracting true local adiabatic effectiveness and the heat transfer coefficient from measurements of surface temperature and surface heat transfer is therefore difficult. In contrast, another cooling parameter, the overall effectiveness (ϕ), is readily obtained from the measurements of surface temperature, internal coolant temperature, and mainstream temperature. The overall effectiveness is a normalized measure of surface temperatures expected for actual operating conditions and is thus an important parameter that drives the life expectancy of a turbine component. Another issue is that scaling ϕ from experimental conditions to engine conditions is dependent on the heat transfer through the part. It has been well-established that the Biot number must be matched for the experimentally measured ϕ to match ϕ at engine conditions. However, the thermal conductivity of both the metal blade and the thermal barrier coating changes substantially from low-temperature to high-temperature engine conditions and usually not in the same proportion. This paper describes a novel method of replicating the correct thermal behavior of the thermal barrier coating (TBC) relative to the metal turbine while obtaining surface temperature measurements and heat fluxes. Furthermore, this paper describes how the ϕ value obtained at the low-temperature conditions can be adjusted to predict ϕ at high-temperature engine conditions when it is impossible to match the Biot number perfectly.

Publisher

ASME International

Subject

Mechanical Engineering

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3