Affiliation:
1. Solar Energy and Energy Conversion Laboratory, Department of Mechanical Engineering, University of Florida, Gainesville, Florida 32611-6300
Abstract
Desiccant cooling systems have the ability to provide efficient humidity and temperature control while reducing the electrical energy requirement for air conditioning as compared to a conventional system. Naturally, the desiccant air dehumidification process greatly influences the overall performance of the desiccant system. Therefore, the effects of variables such as air and desiccant flow rates, air temperature and humidity, desiccant temperature and concentration, and the area available for heat and mass transfer are of great interest. Due to the complexity of the dehumidification process, theoretical modeling relies heavily upon experimental studies. However, a limited number of experimental studies are reported in the literature. This paper presents results from a detailed experimental investigation of the heat and mass transfer between a liquid desiccant (triethylene glycol) and air in a packed bed absorption tower using high liquid flow rates. A high performance packing that combines good heat and mass transfer characteristics with low pressure drop is used. The rate of dehumidification, as well as the effectiveness of the dehumidification process are assessed based on the variables listed above. Good agreement is shown to exist between the experimental findings and predictions from finite difference modeling. In addition, a comparison between the findings in the present study and findings previously reported in the literature is made. The results obtained from this study make it possible to characterize the important variables which impact the system design.
Subject
Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment
Reference29 articles.
1. Chen, L. C., Kuo, C. L., and Shyu, R. J., 1989, “The Performance of a Packed Bed Dehumidifier for Solar Liquid Desiccant Systems,” Proceedings of the 11th Annual ASME Solar Energy Conference, San Diego, California, pp. 371–377.
2. Chung T.-W. , GhoshT. K., HinesA. L., and NovoselD., 1995, “Dehumidiflcation of Moist Air With Simultaneous Removal of Selected Pollutants by Triethylene Glycol Solutions in a Packed-Bed Absorber,” Separation Science and Technology, Vol. 30, pp. 1807–1832.
3. Chung T.-W. , 1994, “Predictions of the Moisture Removal Efficiencies for Packed-Bed Dehumidification Systems,” Gas Separation & Purification, Vol. 8, pp. 265–268.
4. Chung T.-W. , GhoshT. K., and HinesA. L., 1993, “Dehumidification of Air by Aqueous Lithium Chloride in a Packed Column,” Separation Science and Technology, Vol. 28, pp. 533–550.
5. Dow Chemical Company, 1992, “A Guide to Glycols,” Dow Chemical Company, Midland, Michigan.
Cited by
142 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献