Mechanical Evaluation of Polyvinyl Alcohol Cryogels for Covered Stents

Author:

Weaver Jason D.1,Ku David N.2

Affiliation:

1. Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 313 Ferst Drive, Suite 2127, Atlanta, GA 30332

2. George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, 801 Ferst Drive, Atlanta, GA 30332

Abstract

Covered stents could reduce restenosis rates by preventing cellular migration with a physical barrier and may have reduced thrombotic complications if an appropriate material is selected. Previous Dacron™ or poly(tetrafluoroethylene) (PTFE) covered stents have had mixed clinical results in part because they are too thick and too thrombogenic at small diameters. Ideally, the covering should be as thin as a stent strut, mechanically able to expand as much as a stent, and durable enough to withstand deployment. As an alternative to PTFE, thin polyvinyl alcohol (PVA) cryogel membranes were tested for their ability to stretch with uniaxial tension tests and for puncture strength with a modified ASTM method. Additionally, PVA cryogel covered stents were made by coating expanded bare metal stents. These covered stents were then hand-crimped onto a balloon catheter and expanded. PVA cryogel membranes were made as thin as 100 μm—thinner than some stent struts—and stretched to approximately 3.0 times their original diameter (similar to a stent during deployment). PVA cryogel membranes resisted puncture well with an average push-through displacement of 4.77 mm—allowing for safe deployment in vessels of up to 9 mm in diameter. Push-through displacement did not depend on membrane thickness in the range tested—a trait that could reduce stent profile without increased risk of puncture. All the PVA cryogel covered stents tolerated the crimping and expansion process well and there was little to no visible membrane damage. In conclusion, based on the results of these mechanical tests, PVA cryogels are mechanically suitable for covered stent membranes. This work represents a first step toward the creation of a new class of covered stent, which could prevent complications from both restenosis and thrombosis.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3