Lengthening of a Single-Loop Tibialis Tendon Graft Construct After Cyclic Loading: A Study Using Roentgen Stereophotogrammetric Analysis

Author:

Smith Conrad Kay1,Hull M. L.2,Howell S. M.3

Affiliation:

1. Biomedical Engineering Program, University of California, Davis, CA 95616

2. Department of Mechanical Engineering, and Biomedical Engineering Program, University of California, Davis, CA 95616

3. Department of Mechanical Engineering, University of California, Davis, CA 95616

Abstract

Although single-loop tibialis tendon allografts have increased in popularity owing to their many advantages over patellar tendon and double-loop hamstring tendon autografts, some percentage of the patient population do not have clinically stable knees following anterior cruciate ligament reconstruction with single-loop tibialis tendon allografts. Therefore, it would be advantageous to determine the causes of increased anterior laxity which ultimately must be traced to lengthening of the graft construct. One objective of this study was to demonstrate the feasibility of using Roentgen stereophotogrammetric analysis (RSA) to determine the causes of lengthening of a single-loop graft construct subjected to cyclic loading. A second objective was to determine which cause(s) contributes most to an increase in length of this graft construct. Radio-opaque markers were inserted into ten grafts to measure the lengthening at the sites of the tibial and femoral fixations and between the sites of fixation. Each graft was passed through a tibial tunnel in a calf tibia, looped around a rigid cross-pin, and fixed to the tibia with a Washerloc fixation device. The grafts were cyclically loaded for 225,000 cycles from 20to170N. Prior to and at intervals during the cyclic loading, simultaneous radiographs were taken. RSA was used to determine the three-dimensional coordinates of the markers from which the lengthening at the sites of fixation and between the sites of fixation was computed at each interval. The sites of the femoral and tibial fixations were the largest contributors to the increase in length of the graft construct, with maximum average values of 0.68 and 0.55 mm, respectively, after 225,000 cycles. The graft substance between the sites of fixation contributed least to lengthening of the graft, with a maximum average value of 0.31 mm. Ninety percent of the maximum average values occurred before 100,000 cycles of loading for the largest contributors. RSA proved to be a useful method for measuring lengthening due to all three causes. Lengthening of the graft construct at the sites of both fixations is sufficiently large that the combined contributions may manifest as a clinically important increase in anterior laxity.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3