Increased Conformity Offers Diminishing Returns for Reducing Total Knee Replacement Wear

Author:

Fregly Benjamin J.1,Marquez-Barrientos Carlos2,Banks Scott A.1,DesJardins John D.3

Affiliation:

1. Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL 32611-6250; Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131; and Department of Orthopaedics and Rehabilitation, University of Florida, Gainesville, FL 32611-2727

2. Department of Biomedical Engineering, University of Florida, Gainesville, FL 32611-6131

3. Department of Bioengineering, Clemson University, Clemson, SC 29634-0905

Abstract

Wear remains a significant problem limiting the lifespan of total knee replacements (TKRs). Though increased conformity between TKR components has the potential to decrease wear, the optimal amount and planes of conformity have not been investigated. Furthermore, differing conformities in the medial and lateral compartments may provide designers the opportunity to address both wear and kinematic design goals simultaneously. This study used a computational model of a Stanmore knee simulator machine and a previously validated wear model to investigate this issue for simulated gait. TKR geometries with different amounts and planes of conformity on the medial and lateral sides were created and tested in two phases. The first phase utilized a wide range of sagittal and coronal conformity combinations to blanket a physically realistic design space. The second phase performed a focused investigation of the conformity conditions from the first phase to which predicted wear volume was sensitive. For the first phase, sagittal but not coronal conformity was found to have a significant effect on predicted wear volume. For the second phase, increased sagittal conformity was found to decrease predicted wear volume in a nonlinear fashion, with reductions gradually diminishing as conformity increased. These results suggest that TKR geometric design efforts aimed at minimizing wear should focus on sagittal rather than coronal conformity and that at least moderate sagittal conformity is desirable in both compartments.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Design and finite element analysis of total knee replacement (TKR) for additive manufacturing;INTERNATIONAL CONFERENCE ON SMART MATERIALS AND STRUCTURES, ICSMS-2022;2023

2. A review on the wear and failure suppression of artificial knee joint;2022 3rd International Symposium on Artificial Intelligence for Medicine Sciences;2022-10-13

3. Computational Wear Prediction of TKR with Flatback Deformity during Gait;Applied Sciences;2022-04-06

4. Research on the Wear Performance of Artificial Knee Joint with Different Geometric Dimension;Journal of Medical and Biological Engineering;2022-01-15

5. Relationship between the form and function of implant design in total knee replacement;Journal of Biomechanics;2021-04

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3