The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation

Author:

Giambini Hugo1,Dragomir-Daescu Dan2,Huddleston Paul M.3,Camp Jon J.4,An Kai-Nan1,Nassr Ahmad3

Affiliation:

1. Biomechanics Laboratory, Division of Orthopedic Research, Mayo Clinic, Rochester, MN 55905 e-mail:

2. Division of Engineering, Mayo Clinic College of Medicine, Mayo Clinic, Rochester, MN 55905 e-mail:

3. Biomechanics Laboratory, Division of Orthopedic Research, Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905 e-mail:

4. Biomedical Imaging Resource, Department of Radiology, Mayo Clinic College of Medicine, Rochester, MN 55905 e-mail:

Abstract

Osteoporosis is characterized by bony material loss and decreased bone strength leading to a significant increase in fracture risk. Patient-specific quantitative computed tomography (QCT) finite element (FE) models may be used to predict fracture under physiological loading. Material properties for the FE models used to predict fracture are obtained by converting grayscale values from the CT into volumetric bone mineral density (vBMD) using calibration phantoms. If there are any variations arising from the CT acquisition protocol, vBMD estimation and material property assignment could be affected, thus, affecting fracture risk prediction. We hypothesized that material property assignments may be dependent on scanning and postprocessing settings including voltage, current, and reconstruction kernel, thus potentially having an effect in fracture risk prediction. A rabbit femur and a standard calibration phantom were imaged by QCT using different protocols. Cortical and cancellous regions were segmented, their average Hounsfield unit (HU) values obtained and converted to vBMD. Estimated vBMD for the cortical and cancellous regions were affected by voltage and kernel but not by current. Our study demonstrated that there exists a significant variation in the estimated vBMD values obtained with different scanning acquisitions. In addition, the large noise differences observed utilizing different scanning parameters could have an important negative effect on small subregions containing fewer voxels.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering