Darryl E. Metzger Memorial Session Paper: Experimental Heat Transfer and Friction in Channels Roughened With Angled, V-Shaped, and Discrete Ribs on Two Opposite Walls

Author:

Taslim M. E.1,Li T.1,Kercher D. M.2

Affiliation:

1. Department of Mechanical Engineering, Northeastern University, Boston, MA 02115

2. GE Aircraft Engines, General Electric Corporation, Lynn, MA 01910

Abstract

Experimental investigations have shown that the enhancement in heat transfer coefficients for air flow in a channel roughened with angled ribs is on the average higher than that roughened with 90 deg ribs of the same geometry. Secondary flows generated by the angled ribs are believed to be responsible for these higher heat transfer coefficients. These secondary flows also create a spanwise variation in heat transfer coefficient on the roughened wall with high levels of heat transfer coefficient at one end of the rib and low levels at the other end. In an effort basically to double the area of high heat transfer coefficients, the angled rib is broken at the center to form a V-shaped rib, and tests are conducted to investigate the resulting heat transfer coefficients and friction factors. Three different square rib geometries, corresponding to blockage ratios of 0.083, 0.125, and 0.167, with a fixed pitch-to-height ratio of 10, mounted on two opposite walls of a square channel in a staggered configuration, are tested in a stationary channel for 5000 < Re < 30,000. Heat transfer coefficients, friction factors, and thermal performances are compared with those of 90 deg, 45 deg, and discrete angled ribs. The V-shaped ribs are tested for both pointing upstream and downstream of the main flow. Test results show that: (a) 90 deg ribs represent the lowest thermal performance, based on the same pumping power, and is essentially the same for the 2:1 change in blockage ratio, (b) low-blockage-ratio (e/Dh = 0.083) V-shaped ribs pointing downstream produced the highest heat transfer enhancement and friction factors. Among all other geometries with blockage ratios of 0.125 and 0.167, 45 deg ribs showed the highest heat transfer enhancements with friction factors less than those of V-shaped ribs, (c) thermal performance of 45 deg ribs and the lowest blockage discrete ribs are among the highest of the geometries tested in this investigation, and (d) discrete angled ribs, although inferior to 45 deg and V-shaped ribs, produce much higher heat transfer coefficients and lower friction factors compared to 90 deg ribs.

Publisher

ASME International

Subject

Mechanical Engineering

Reference29 articles.

1. Abuaf, N., Gibbs, R., and Baum, R., 1986, “Pressure Drop and Heat Transfer Coefficient Distributions in Serpentine Passages With and Without Turbulence Promoters,” The Eighth International Heat Transfer Conference, C. L. Tien, V. P. Carey, and J. K. Ferrel, eds., pp. 2837–2845.

2. Burggraf, F., 1970, “Experimental Heat Transfer and Pressure Drop With Two Dimensional Turbulence Promoters Applied to Two Opposite Walls of a Square Tube,” Augmentation of Convective Heat and Mass Transfer, A. E. Bergles and R. L. Webb, eds., ASME, New York, pp. 70–79.

3. Chandra P. R. , HanJ. C., and LauS. C., 1988, “Effect of Rib Angle on Local Heat/Mass Transfer Distribution in a Two-Pass Rib-Roughened Channel,” ASME JOURNAL OF TURBOMACHINERY, Vol. 110, pp. 233–241.

4. Chandra P. R. , and HanJ. C., 1989, “Pressure Drop and Mass Transfer in Two-Pass Ribbed Channels,” AIAA J. Thermophysics, Vol. 3, No. 3, pp. 315–319.

5. Colburn , 1933, “A Method of Correlating Forced Convection Heat Transfer Data and a Comparison With Fluid Friction,” Trans. AIChE, Vol. 29, pp. 174–210.