Affiliation:
1. Department of Mechanical, Industrial and Nuclear Engineering, University of Cincinnati, Cincinnati, OH 45221-0072
Abstract
Experimental heat transfer and isothermal pressure drop data for single-phase water flows in a plate heat exchanger (PHE) with chevron plates are presented. In a single-pass U-type counterflow PHE, three different chevron plate arrangements are considered: two symmetric plate arrangements with β = 30 deg/30 deg and 60 deg/60 deg, and one mixed-plate arrangement with β = 30 deg/60 deg. For water (2 < Pr < 6) flow rates in the 600 < Re < 104 regime, data for Nu and f are presented. The results show significant effects of both the chevron angle β and surface area enlargement factor φ. As β increases, and compared to a flat-plate pack, up to two to five times higher Nu are obtained; the concomitant f, however, are 13 to 44 times higher. Increasing φ also has a similar, though smaller effect. Based on experimental data for Re a 7000 and 30 deg ≤ β ≤ 60 deg, predictive correlations of the form Nu = C1,(β) D1(φ) Rep1(β)Pr1/3(μ/μw)0.14 and f = C2(β) D2(φ) Rep2(β) are devised. Finally, at constant pumping power, and depending upon Re, β, and φ, the heat transfer is found to be enhanced by up to 2.8 times that in an equivalent flat-plate channel.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Reference30 articles.
1. Bergles, A. E., 1985, “Techniques to Augment Heat Transfer,” Handbook of Heat Transfer Applications, 2nd Ed., W. M. Roshenow et al., eds., McGraw-Hill, New York, Chapter 3.
2. Ding
J.
, and ManglikR. M., 1996, “Analytical Solutions for Laminar Fully Developed Flows in Double-Sine Shaped Ducts,” Heat and Mass Transfer, Vol. 31, pp. 269–277.
3. Focke
W. W.
, ZachariadesJ., and OlivierI., 1985, “The Effect of the Corrugation Inclination Angle on the Thermohydraulic Performance of Plate Heat Exchangers,” International Journal of Heat and Mass Transfer, Vol. 28, pp. 1469–1479.
4. Gasier, G., and Kottke, V., 1990, “Effects of Corrugation Parameters on Local and Integral Heat Transfer in Plate Heat Exchangers and Regenerators,” Heat Transfer 1990, Vol. 5, G. Hetsroni, ed., Hemisphere, New York, pp. 85–90.
5. Heavner
R. L.
, KumarH., and WanniarachchiA. S., 1993, “Performance of an Industrial Plate Heat Exchanger: Effect of Chevron Angle,” AIChE Symposium Series, Vol. 89, No. 295, pp. 262–267.
Cited by
274 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献