Abstract

Cartilage mechanical function relies on a composite structure of a collagen fibrillar network entrapping a proteoglycan matrix. Previous biphasic or poroelastic models of this tissue, which have approximated its composite structure using a homogeneous solid phase, have experienced difficulties in describing measured material responses. Progress to date in resolving these difficulties has demonstrated that a constitutive law that is successful for one test geometry (confined compression) is not necessarily successful for another (unconfined compression). In this study, we hypothesize that an alternative fibril-reinforced composite biphasic representation of cartilage can predict measured material responses and explore this hypothesis by developing and solving analytically a fibril-reinforced biphasic model for the case of uniaxial unconfined compression with frictionless compressing platens. The fibrils were considered to provide stiffness in tension only. The lateral stiffening provided by the fibril network dramatically increased the frequency dependence of disk rigidity in dynamic sinusoidal compression and the magnitude of the stress relaxation transient, in qualitative agreement with previously published data. Fitting newly obtained experimental stress relaxation data to the composite model allowed extraction of mechanical parameters from these tests, such as the rigidity of the fibril network, in addition to the elastic constants and the hydraulic permeability of the remaining matrix. Model calculations further highlight a potentially important difference between homogeneous and fibril-reinforced composite models. In the latter type of model, the stresses carried by different constituents can be dissimilar, even in sign (compression versus tension) even though strains can be identical. Such behavior, resulting only from a structurally physiological description, could have consequences in the efforts to understand the mechanical signals that determine cellular and extracellular biological responses to mechanical loads in cartilage.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 202 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3