Analysis of Timewise Compressor Fouling Phenomenon on a Multistage Test Compressor: Performance Losses and Particle Adhesion1

Author:

Vulpio Alessandro1,Suman Alessio1,Casari Nicola1,Pinelli Michele1,Kurz Rainer2,Brun Klaus3

Affiliation:

1. Engineering Department, University of Ferrara, Ferrara, IT 44122

2. Solar Turbines Inc., San Diego, CA 92123

3. Elliott Group, Ebara Corp., Jeannette, PA 15644

Abstract

Abstract The analysis of the performance losses of a multistage compressor concerning the air contaminant is not widespread in literature and, the mutual interactions of particle materials, air humidity, and compressor load are not well studied. The airborne micrometric particles that enter the compressor can deposit on the internal surfaces, causing the loss of performance of the machine. In this paper, several experimental tests have been carried out on a multistage compressor unit. A detailed analysis has been carried out considering soil and soot ingestion, as well as the air relative humidity (RH) (ranging from 50% RH to 80% RH) and compressor rotating velocity. Several combinations of particle diameter, material, and operating conditions have been considered. The amount of contaminant at the compressor outlet has been measured and the capture efficiency of the whole machine has been determined. Over the exposure time, the capture efficiency ranges from 0.2 to 0.6 according to the powder type and compressor inlet conditions. The capability of the compressor to collect particles changes over time as a function of the condition, even if several tested cases appear characterized by an almost constant capture efficiency trend. In addition, the performance degradation has been monitored over time and, with the reference of the particle concentration, the present experimental campaign covers about 500 operating hours of an actual installation. After a detailed evaluation of experimental uncertainty, the performance losses due to particle contamination have been assessed. The losses in the compressor performance have been estimated by means of the pressure ratio of the axial stages. The maximum degradation has been estimated equal to 0.53%/h for the compressor pressure ratio. Soot particles appear stickier, especially in the presence of higher humidity and represent the most detrimental operating conditions for the compressor unit.

Publisher

ASME International

Subject

Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering

Reference40 articles.

1. A Compressor Fouling Review Based on an Historical Survey of ASME Turbo Expo Papers;ASME J. Turbomach.,2017

2. Gas Turbine Fouling Tests: Review, Critical Analysis and Impact Behavior Map;ASME J. Eng. Gas Turbines Power,2019

3. Generalization of Particle Impact Behavior in Gas Turbine Via Non-Dimensional Grouping;Prog. Energy Combust. Sci.,2019

4. Experience in the Operation of Air Filters in Gas Turbine Installations,1984

5. Gas Turbine Compressor Operating Environment and Material Evaluation,1989

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3