Fundamental Roles of Axial Stretch in Isometric and Isobaric Evaluations of Vascular Contractility

Author:

Caulk Alexander W.1,Humphrey Jay D.23,Murtada Sae-Il4

Affiliation:

1. Department of Biomedical Engineering, Yale University, New Haven, CT 06520

2. Fellow ASME Department of Biomedical Engineering, Yale University, New Haven, CT 06520;

3. Vascular Biology and Therapeutics Program, Yale University, New Haven, CT 06520

4. Department of Biomedical Engineering, Yale University, 55 Prospect Street, New Haven, CT 06520 e-mail:

Abstract

Vascular smooth muscle cells (VSMCs) can regulate arterial mechanics via contractile activity in response to changing mechanical and chemical signals. Contractility is traditionally evaluated via uniaxial isometric testing of isolated rings despite the in vivo environment being very different. Most blood vessels maintain a locally preferred value of in vivo axial stretch while subjected to changes in distending pressure, but both of these phenomena are obscured in uniaxial isometric testing. Few studies have rigorously analyzed the role of in vivo loading conditions in smooth muscle function. Thus, we evaluated effects of uniaxial versus biaxial deformations on smooth muscle contractility by stimulating two regions of the mouse aorta with different vasoconstrictors using one of three testing protocols: (i) uniaxial isometric testing, (ii) biaxial isometric testing, and (iii) axially isometric plus isobaric testing. Comparison of methods (i) and (ii) revealed increased sensitivity and contractile capacity to potassium chloride and phenylephrine (PE) with biaxial isometric testing, and comparison of methods (ii) and (iii) revealed a further increase in contractile capacity with isometric plus isobaric testing. Importantly, regional differences in estimated in vivo axial stretch suggest locally distinct optimal biaxial configurations for achieving maximal smooth muscle contraction, which can only be revealed with biaxial testing. Such differences highlight the importance of considering in vivo loading and geometric configurations when evaluating smooth muscle function. Given the physiologic relevance of axial extension and luminal pressurization, we submit that, when possible, axially isometric plus isobaric testing should be employed to evaluate vascular smooth muscle contractile function.

Funder

National Heart, Lung, and Blood Institute

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering