Electrochemical Bioelectronics in Drug Delivery: Effect of the Initial Gas Volume

Author:

Avila Raudel1,Ciatti Joanna L.2,Vázquez-Guardado Abraham3,Wu Yixin2,Zhang Yamin3,Garziera Rinaldo4,Rogers John A.5,Huang Yonggang6

Affiliation:

1. Department of Mechanical Engineering, Northwestern University, Evanston, IL 60208

2. Department of Materials Science and Engineering, Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208

3. Querrey Simpson Institute for Bioelectronics, Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL 60208

4. Dipartimento di Ingegneria ed Architettura, Universita’ di Parma, Parma 43121, Italy

5. Querrey Simpson Institute for Bioelectronics, Center for Bio-Integrated Electronics, Department of Mechanical Engineering, Department of Materials Science and Engineering, Department of Biomedical Engineering, Department of Electrical and Computer Engineering, Department of Chemistry, Department of Neurological Surgery, Northwestern University, Evanston, IL 60208

6. Querrey Simpson Institute for Bioelectronics, Center for Bio-Integrated Electronics, Department of Mechanical Engineering, Department of Materials Science and Engineering, Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208

Abstract

Abstract Implantable bioelectronic devices with drug delivery capabilities have emerged as suitable candidates for biomedical applications focusing on localized drug delivery. These classes of miniaturized bioelectronics offer wireless operation and refillable designs that can be used for repeated animal behavioral studies without restricting their motion. The pumping mechanisms of these bioelectronic devices features soft materials, microfluidics, and electrochemical subsystems that can be scaled from behavioral studies in small animals to delivery of life-saving medication in humans. Here, we study the refillable aspect of these bioelectronic systems using an analytic model for the drug delivery time established from the ideal gas law when an initial gas volume is present in the device electrolyte reservoirs. The effect of the initial gas volume in delaying the drug delivery time is captured via a non-dimensional parameter identified as the normalized initial gas volume. An analytical solution is derived from the perturbation method, which agrees well with the numerical solution. These results have relevance in the reusability aspect of these bioelectronic systems since modifying the amount of initial gas in the device reservoirs for different experiments affects the total delivery time and can serve as a tunable parameter to ensure timely and successful delivery of the drug in the target region.

Funder

Division of Graduate Education

Ford Foundation

National Institute on Drug Abuse

Publisher

ASME International

Subject

Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3