Investigation of Tip Leakage Vortex Breakdown in a High-Speed Multistage Axial Compressor

Author:

Seki Ryosuke1,Azuma Toshihiko1,Iwatani Junji1,Nakaniwa Akihiro1,Okui Hidetaka2,Shibata Takanori3

Affiliation:

1. Mitsubishi Heavy Industries, Ltd. Research & Innovation Center, , 2-1-1 Shinhama, Arai, Takasago, Hyogo 676-8686 , Japan

2. Mitsubishi Heavy Industries, Ltd. Gas Turbine Engineering Department, , 2-1-1 Shinhama, Arai, Takasago, Hyogo 676-8686 , Japan

3. Iwate University Faculty of Science and Engineering, , 4-3-5 Ueda, Morioka, Iwate 020-8551 , Japan

Abstract

AbstractIn this article, an unsteady tip leakage flow instability is identified and investigated for an axial compressor at near-surge conditions. We describe the results of experimental verification of a new compressor developed by improving the blade geometry based on the criterion for the occurrence of this unsteady phenomenon. In a high-speed multistage axial flow compressor having a subsonic high stagger rotor blade, a surge test was carried out by changing the tip clearance. Under a condition of large tip clearance, a drastic decrease in the static pressure rise coefficient near the surge point was observed. At this operating condition, large, unsteady pressure fluctuation at the blade tip was confirmed, and the occurrence of tip leakage vortex breakdown was clarified by unsteady multipoint pressure measurement and detailed unsteady numerical simulations. Due to the blockage effect caused by vortex breakdown of the tip leakage, double leakage and axially reversed flow near the trailing edge were observed. It was found that the vortex breakdown region of the tip leakage vortex propagated in the circumferential direction and caused the rotating instability. In order to investigate the relationship among this unsteady flow phenomenon, tip clearance size, and flow pattern, unsteady calculation was conducted by changing the blade tip stagger and tip clearance size. A new concept of tip clearance of staggered pitch reference was proposed, which makes it possible to include the effect of blade loading on the clearance and clarifies that there exists a threshold at which vortex breakdown occurs/does not occur. On the basis of the aforementioned results, a high-speed multistage improved compressor was designed and manufactured to prevent tip leakage vortex breakdown. A clearance change test using active clearance control technology was conducted, and an increase in the static pressure rise coefficient near the surge point was confirmed for each clearance. The design concept of the improved blade, which suppressed the unsteady tip leakage flow instability, was tested and verified, and the effectiveness of the design guideline in actual gas turbines for power generation was confirmed.

Publisher

ASME International

Subject

Mechanical Engineering

Reference28 articles.

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3