Preliminary Mechanical Characterization of the Small Bowel for In Vivo Robotic Mobility

Author:

Terry Benjamin S.,Lyle Allison B.1,Schoen Jonathan A.2,Rentschler Mark E.3

Affiliation:

1. Department of Mechanical Engineering, University of Colorado at Boulder, 427 UCB, 1111 Engineering Drive, Boulder, CO 80309-0427

2. University of Colorado at Denver, 12631 E 14th Avenue, Aurora, CO 80045e-mail:

3. University of Colorado at Boulder, 427 UCB, 1111 Engineering Drive, Boulder, CO 80309-0427 e-mail:

Abstract

In this work we present test methods, devices, and preliminary results for the mechanical characterization of the small bowel for intra luminal robotic mobility. Both active and passive forces that affect mobility are investigated. Four investigative devices and testing methods to characterize the active and passive forces are presented in this work: (1) a novel manometer and a force sensor array that measure force per cm of axial length generated by the migrating motor complex, (2) a biaxial test apparatus and method for characterizing the biomechanical properties of the duodenum, jejunum, and ileum, (3) a novel in vitro device and protocol designed to measure the energy required to overcome the self-adhesivity of the mucosa, and (4) a novel tribometer that measures the in vivo coefficient of friction between the mucus membrane and the robot surface. The four devices are tested on a single porcine model to validate the approach and protocols. Mean force readings per cm of axial length of intestine that occurred over a 15 min interval in vivo were 1.34 ± 0.14 and 1.18 ± 0.22 N cm−1 in the middle and distal regions, respectively. Based on the biaxial stress/stretch tests, the tissue behaves anisotropically with the circumferential direction being more compliant than the axial direction. The mean work per unit area for mucoseparation of the small bowel is 0.08 ± 0.03 mJ cm−2. The total energy to overcome mucoadhesion over the entire length of the porcine small bowel is approximately 0.55 J. The mean in vivo coefficient of friction (COF) of a curved 6.97 cm2 polycarbonate sled on live mucosa traveling at 1 mm s−1 is 0.016 ± 0.002. This is slightly lower than the COF on excised tissue, given the same input parameters. We have initiated a comprehensive program and suite of test devices and protocols for mechanically characterizing the small bowel for in vivo mobility. Results show that each of the four protocols and associated test devices has successfully gathered preliminary data to confirm the validity of our test approach.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Cited by 44 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3