Modeling of the Plane Needle Cutting Edge Rake and Inclination Angles for Biopsy

Author:

Moore Jason Z.1,Zhang Qinhe2,McGill Carl S.3,Zheng Haojun4,McLaughlin Patrick W.5,Shih Albert J.6

Affiliation:

1. Department of Mechanical Engineering, University of Michigan, Ann Arbor, MI 48109

2. Department of Mechanical Engineering, Shandong University, Jinan, Shandong 250100, China

3. Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109

4. Department of Precision Instrument and Mechanology, Tsinghua University, Beijing 100084, China

5. Department of Radiation Oncology, University of Michigan, Ann Arbor, MI 48109

6. Department of Mechanical Engineering, and Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109

Abstract

Hollow needles are one of the most common medical devices, yet little study has focused on the needle tip cutting geometry for biopsy, which is a tissue cutting process. This research develops mathematical models to calculate the inclination and rake angles along cutting edges on needle tips generated by planes. Three types of plane needle tips, the one-plane bias bevel, multi-plane symmetrical, and two-plane nonsymmetric needles, are investigated. The models show that the leading tip of a bias bevel needle has an inclination angle of 0 deg, the worst configuration for cutting. Symmetric multiplane needles on the other hand have very high inclination angles, 60, 56.3, and 50.8 deg, given a needle formed by two-, three-, and four-plane, respectively, for a bevel angle of 30 deg and can assist more effective needle biopsy. The rake angle is at its greatest value (the best configuration for cutting), which equals the 90 deg minus the bevel angle, at the initial cutting point for the bias bevel needle. Experiments are performed using three 11 gauge two-plane symmetric needles with 20, 25, and 30 deg bevel angles on bovine liver and demonstrate that the needle tip geometry affects biopsy performance, where longer biopsy samples are collected with needles of higher rake and inclination angle.

Publisher

ASME International

Subject

Industrial and Manufacturing Engineering,Computer Science Applications,Mechanical Engineering,Control and Systems Engineering

Reference15 articles.

1. Prostate Biopsy Outcome Using 29 mm Cutting Length;Fink;Urol. Int.

2. Needle Core Length in Sextant Biopsy Influences Prostate Cancer Detection Rate;Iczkowski;Urology

3. Improving Glandular Coverage During Prostate Biopsy Using a Long-Core Needle: Technical Performance of an End-Cutting Needle;Ubhayakar;BJU Int.

4. Blade Oblique Cutting of Tissue for Investigation of Biopsy Needle Insertion;Moore;Trans. NAMRI/SME

5. Robotic Needle Insertion: Effects of Friction and Needle Geometry;O’Leary

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献