Turbine Efficiency
Measurement System for the QinetiQ Turbine Test
Facility
Author:
Beard Paul F.1, Povey Thomas1, Chana Kamaljit
S.2
Affiliation:
1. Department of Engineering Science, University of Oxford, Parks Road, Oxfordshire, OX1 3PJ, UK 2. QinetiQ Ltd., Cody Technology Park, Ively Road, Farnborough, GU14 0LX, UK
Abstract
Abstract
A turbine efficiency measurement system has been developed and installed on the turbine test facility (TTF) at QinetiQ Farnborough. The TTF is an engine-scale short-duration (0.5s run time) rotating transonic facility, which can operate as either single stage (HP vane and rotor) or 112 stage (HP stage with IP or LP vane). The current MT1 HP stage is highly loaded and unshrouded and is therefore relevant to current design trends. Implementation of the efficiency measurement system forms part of the EU Turbine Aero-Thermal External Flows (TATEF II) program. The following aspects of the efficiency measurement system are discussed in this paper: mass-flow rate measurement, power measurement by direct torque measurement, turbine inlet and exit area traverse measurement systems, computation of efficiency by mass weighting, and uncertainty analysis of the experimentally determined turbine efficiency. The calibration of the mass-flow rate and torque measurement systems are also discussed. Emphasis was placed on the need for a low efficiency precision uncertainty, so that changes in efficiency associated with turbine inlet temperature distortion and swirl can be resolved with good accuracy. Measurements with inlet flow distortion form part of the TATEF II program and will be the subject of forthcoming publications.
Publisher
ASME International
Subject
Mechanical Engineering
Reference27 articles.
1. Epstein, A. H., and Guenette, G. R., 1984, “The MIT Blowdown Facility,” ASME Paper No. 84-GT-116. 2. Hilditch, M. A., Fowler, A., Jones, T. V., Chana, K. S., Oldfield, M. L. G., Ainsworth, R. W., Hogg, S. I., Anderson, S. J., and Smith, G. C., 1994, “Installation of a Turbine Stage in the Pyestock Isentropic Light Piston Facility,” ASME Paper No. 94-GT-277. 3. Ainsworth, R. W., Schultz, D. L., Davies, M. R. D., Forth, C. J. P., Hilditch, M. A., Oldfield, M. L. G., and Sheard, A. G., 1988, “A Transient Flow Facility for the Study of the Thermofluid-Dynamics of a Full Stage Turbine Under Engine Representative Conditions,” ASME Paper No. 88-GT-144. 4. Sieverding, C. H., and Arts, T., 1992, “The VKI Compression Tube Annular Cascade Facility CT3,” ASME Paper No. 92-GT-336. 5. Guenette, G. R., Epstein, A. H., and Ito, E., 1989, “Turbine Aerodynamic Performance Measurements in Short Duration Facilities,” AIAA Paper No. 89-2690.
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|