The Effect of Different Sterilization Methods on Polypropylene Syringes

Author:

Selcan Turker N.12,Yekta Özer A.3,Kutlu Burak4,Nohutcu Rahime4,Colak Seyda5,Ekizoglu Melike6,Özalp Meral6

Affiliation:

1. Department of Radiopharmacy, Faculty of Pharmacy, Hacettepe University, Sıhhiye 06100, Ankara, Turkey;

2. Harvard Medical School, MGH Athinoula A. Martinos Center for Biomedical Imaging, Boston, MA 02129

3. Department of Radiopharmacy, Faculty of Pharmacy, Hacettepe University, Sıhhiye 06100, Ankara, Turkey e-mail:

4. Department of Periodontology, Faculty of Dentistry, Hacettepe University, Sıhhiye 06100, Ankara, Turkey

5. Department of Physics Engineering, Faculty of Engineering, Hacettepe University, Sıhhiye 06100, Ankara, Turkey

6. Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Hacettepe University, Sıhhiye 06100, Ankara, Turkey

Abstract

This presents the influence of gamma irradiation on Pharmacopeia specifications, mechanical and flow parameters of polypropylene (PP) syringes. There has been significant progress in the terminal sterilization of single-use, disposable medical devices with gamma radiation sterilization due to the growing awareness of toxic residues during the ethylene oxide (EtO) sterilization. PP is a widely used polymer for the production of syringes because of its excellent mechanical and thermal properties and has expanded continuously over the last decade. Although 25 kGy was generally recommended for the gamma radiation sterilization of medical products, this radiation dose is high enough to produce substantial damage. Electron spin resonance (ESR) characteristics of irradiated syringes were also studied at normal (25 °C, 60% relative humidity) and accelerated (40 °C, 75% relative humidity) stability test conditions. It was found that the chemical and radiolytic changes and sterility assurance levels (SAL) after gamma radiation sterilization were different in PP syringes. It was shown that for two commercial syringes, E1 and E3, a SAL of 10−4 could be attained with only 10 kGy, with there being less detrimental radiation effects on E1. The differences in the radiosensitivity of the propylene syringes could be due to the different formulations and manufacturing processes. The results indicated that a commercial syringe, identified as E1 could be safely sterilized with gamma irradiation as the radicals decay over a period of days under normal conditions and quenched much faster under stability conditions. Furthermore, ESR technique could be used successfully in monitoring the radiosterilization of this material. Additionally, the confirmation and validation of the SAL doses which are below 25 kGy, will decrease the time and cost of the sterilization with less damaging effects of ionizing irradiation.

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference41 articles.

1. EU and Member State Medical Devices Regulation;Int. J. Technol. Assess. Health Care,2003

2. Biomedical Applications of Polymer-Composite Materials: A Review;Compos. Sci. Technol.,2001

3. Classification of Biomaterials Used in Medicine;Int. J. Adv. Appl. Sci.,2012

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3