Computational Fluid Dynamics of a Vascular Access Case for Hemodialysis
Author:
Ene-Iordache Bogdan1, Mosconi Lidia1, Remuzzi Giuseppe12, Remuzzi Andrea1
Affiliation:
1. Clinical Research Center for Rare Diseases Aldo e Cele Dacco`, Mario Negri Institute for Pharmacological Research, Villa Camozzi, Ranica (BG), Italy 2. Nephrology and Dialysis Unit, Azienda Ospedaliera Ospedali Riuniti di Bergamo, Bergamo, Italy
Abstract
Vascular accesses (VA) for hemodialysis are usually created by native arteriovenous fistulas (AVF) or synthetic grafts. Maintaining patency of VA continues to be a major problem for patients with end-stage renal disease, since in these vessels thrombosis and intimal hyperplasia often occur. These lesions are frequently associated with disturbed flow that develops near bifurcations or sharp curvatures. We explored the possibility of investigating blood flow dynamics in a patient-specific model of end-to-end native AVF using computational fluid dynamics (CFD). Using digital subtraction angiographies of an AVF, we generated a three-dimensional meshwork for numerical analysis of blood flow. As input condition, a time-dependent blood waveform in the radial artery was derived from centerline velocity obtained during echo-color-Doppler ultrasound examination. The finite element solution was calculated using a fluid-dynamic software package. In the straight, afferent side of the radial artery wall shear stress ranged between 20 and 36 dynes/cm2, while on the inner surface of the bending zone it increased up to 350 dynes/cm2. On the venous side, proximal to the anastomosis, wall shear stress was oscillating between negative and positive values (from −12 dynes/cm2 to 112 dynes/cm2), while distal from the anastomosis, the wall shear stress returned within the physiologic range, ranging from 8 to 22 dynes/cm2. Areas of the vessel wall with very high shear stress gradient were identified on the bending zone of the radial artery and on the venous side, after the arteriovenous shunt. Secondary blood flows were also observed in these regions. CFD gave a detailed description of blood flow field and showed that this approach can be used for patient-specific analysis of blood vessels, to understand better the role of local hemodynamic conditions in the development of vascular lesions.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference29 articles.
1. Feldman, H. I., Kobrin, S., and Wasserstein, A., 1996, “Hemodialysis Vascular Access Morbidity,” J. Am. Soc. Nephrol., 7, pp. 523–535. 2. Yerdel, M. A., Kesenci, M., Yazicioglu, K. M., Do¨seyen, Z., Tu¨rkcapar, A. G., and Anadol, E., 1997, “Effect of Haemodynamic Variables on Surgically Created Arteriovenous Fistula Flow,” Nephrol. Dial Transplant, 12, pp. 1684–1688. 3. Kanterman, R. Y., Vesely, T. M., Pilgram, T. K., Guy, B. W., Windus, D. W., and Picus, D., 1995, “Dialysis Access Grafts: Anatomic Location of Venous Stenosis and Results of Angioplasty,” Radiology, 195, pp. 135–139. 4. Giddens, D. P., Zarins, C. K., and Glagov, S., 1993, “The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis,” ASME J. Biomech. Eng., 115, pp. 588–594. 5. Ku, D. N., Giddens, D. P., Zarins, C. K., and Glagov, S., 1985, “Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation,” Arteriosclerosis 5, No. 3, pp. 293–302.
Cited by
52 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|