Abstract

Abstract The threshold for surgical stabilization for an open-book pelvic fracture is not well defined. The purpose of this research was to validate the biomechanical behavior of a specimen-specific pelvic finite element (FE) model with an open-book fracture with the biomechanical behavior of a cadaveric pelvis in double leg stance configuration under physiologic loading, and to utilize the validated model to compare open book versus intact strain patterns during gait. A cadaveric pelvis was experimentally tested under compressive loading in double leg stance, intact, and with a simulated open-book fracture. An intact FE model of this specimen was reanalyzed with an equivalent simulated open-book fracture. Comparison of the FE generated and experimentally measured strains yielded an R2 value of 0.92 for the open-book fracture configuration. Strain patterns in the intact and fractured models were compared throughout the gait cycle. In double leg stance and heel-strike/heel-off models, tensile strains decreased, especially in the pubic ramus contralateral to the injury, and compressive strains increased in the sacroiliac region of the injured side. In the midstance/midswing gait configuration, higher tensile and compressive FE strains were observed on the midstance side of the fractured versus intact model and decreased along the superior and inferior pubic rami and ischium, with midswing side strains reduced almost to zero in the fractured model. Identified in silico patterns align with clinical understanding of open-book fracture pathology suggesting future potential of FE models to quantify instability and optimize fixation strategies.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference38 articles.

1. Critical Management of Deadly Pelvic Injuries;J. Emer. Med. Serv.,2014

2. Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies;ASME J. Biomech. Eng.,2005

3. Validation of a Finite Element Model of the Human Metacarpal;Med. Eng. Phys.,2005

4. Development and Validation of a Three-Dimensional Finite Element Model of the Pelvic Bone;ASME J. Biomech. Eng.,1995

5. Analysis of the Structural Behavior of the Pelvis During Lateral Impact Using the Finite Element Method;Acc. Anal. Prev.,1999

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献