A Novel Intermediate Attachment to Reduce Contamination in Reusable Core Needle Biopsy Devices

Author:

Berges Alexandra J.1,Callanan Megan2,Zawicki Valerie2,Shi Richard2,Athey Thomas2,Ayyappan Vinay2,Metzger Schuyler2,Farrell Alanna2,Manbachi Amir1,Harvey Susan3,Durr Nicholas J.1

Affiliation:

1. Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218; The Center for Bioengineering Innovation and Design, Baltimore, MD 21218; The Johns Hopkins University School of Medicine, Baltimore, MD 21218

2. Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218; The Center for Bioengineering Innovation and Design, Baltimore, MD 21218

3. Department of Radiology, Johns Hopkins Medical Institutions, Baltimore, MD 21287

Abstract

Abstract One barrier to breast cancer diagnosis in low-resource settings is that devices for core needle biopsy (CNB) are either disposable and expensive, or reusable and susceptible to internal contamination. Through interviews with field workers and verification experiments, we identified that a common, commercially available, reusable CNB device allows contaminants to enter the driver chamber during firing, necessitating laborious cleaning of the entire device after every use. We introduce a novel CNB device attachment that eliminates this contamination mode and interfaces with existing commercial reusable drivers and low-cost disposable needles. This attachment repositions the driver–needle connection to the exterior of the driver, preventing retrograde flow of blood. Using an unmodified commercial CNB, we replicate chamber contamination by firing into a body fluid-mimicking glycerol solution. Prototypes were tested for their performance in eliminating this contamination. We tested the effectiveness of a cleaning procedure to reduce trace contamination by using a fluorescent dye and measuring the intensity of fluorescence after cleaning. The device's ability to reliably and consistently biopsy tissue with the novel attachment was evaluated using breast tissue models. In these tests, a reusable CNB with our attachment exhibited no measurable internal contamination, and maintained full biopsy functionality as measured by tissue sample weight and length. Minimizing internal device contamination would simplify the cleaning process for reusable biopsy devices. This would improve the accessibility of breast cancer biopsies in low- and middle-income countries (LMICs).

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3