Experimental Analysis of the Improvement of Heat Transfer in Tube Heat Exchangers Via Passive Flow Generators Using Wire Coil Inserts

Author:

Ibrahim Farah Arina1,Muhamad Mohd Ridha23ORCID,Mohd Zubir Mohd Nashrul23,Omar Mohd Bin45,Siri Zailan4,Hasan Rony Mehedy15,Eid Mohamed Moustafa Abdelhalim Ahmed15ORCID

Affiliation:

1. Department of Mechanical Engineering, Faculty of Engineering, University of Malaya , Kuala Lumpur 50603, Malaysia

2. Department of Mechanical Engineering, Faculty of Engineering, University of Malaya , Kuala Lumpur 50603, Malaysia ; , Kuala Lumpur 50603, Malaysia

3. Centre of Advanced Manufacturing and Material Processing (AMMP Centre), University of Malaya , Kuala Lumpur 50603, Malaysia ; , Kuala Lumpur 50603, Malaysia

4. Institute of Mathematical Sciences, University of Malaya , Kuala Lumpur 50603, Malaysia

5. University of Malaya

Abstract

Abstract Due to their high performance and low-cost demands, internally treated tube heat exchanger surfaces are one of the passive heat transfer enhancements that have caught the industry's attention. At bulk temperatures of 30 °C, an experiment for the insertion of 1 mm and 0.5 mm wire coils with a constant pitch length of 8 mm was carried out in this study. The results on the improvement of heat transfer, including the velocity profile, Nusselt number (6000 < Re < 20,000), friction factor, and thermal enhancement efficiency, were significant. Based on a lower surface temperature recorded beyond the uncertainty value, the results demonstrated an improvement in heat transfer for smaller diameter of wire coil inserts. It's interesting that this improvement is concentrated at low Reynolds numbers, indicating that there may be a point at which an increase in wire thickness does not necessarily result in an equivalent improvement in heat transfer. For both wire thicknesses, a Nusselt number increase of up to five times was visible. The friction factor penalty, however, varies depending on the wire thickness, with a higher magnitude (3.2-fold increase) obtained for 1 mm as opposed to a 1.8-fold increase for the lower counterpart. This distinction results in the 0.5 mm coil insert gaining better overall performance with an average of 2.2 for the thermal performance ratio, further solidifying the advantage of this technique for enhancing heat transfer in conduits. The diameter of the wire coil is found to be a key factor in improving heat transfer and convection on the boundary layer surface.

Funder

Universiti Malaya

Publisher

ASME International

Reference52 articles.

1. Experimental Study of the Thermal Performance of Corrugated Helically Coiled Tube-in-Tube Heat Exchanger;Front. Heat Mass Transfer,2023

2. Thermal Performance Evaluation of a Helically-Micro-Grooved Heat Pipe Working With Water and Aqueous Al2O3 Nanofluid at Different Inclination Angle and Filling Ratio;Appl. Therm. Eng.,2017

3. The Effect of Manufacturing Limitations on Groove Design and Its Implementation to an Algorithm for Determining Heat Transport Capability of Heat Pipes;J. Therm. Sci. Technol.,2017

4. Pipe Internal Grooving Using Closed Magnetic Field System: A Novel Method;Mat. Sci. Eng. Technol.,2022

5. An Overview of Heat Transfer Enhancement Methods and New Perspectives: Focus on Active Methods Using Electroactive Materials;Int. J. Heat Mass Transfer,2013