The Modified Super-Ellipsoid Yield Criterion for Human Trabecular Bone
Author:
Bayraktar Harun H.1234, Gupta Atul1234, Kwon Ron Y.1234, Papadopoulos Panayiotis1234, Keaveny Tony M.1234
Affiliation:
1. Orthopaedic Biomechanics Laboratory, University of California, Berkeley, CA, 2. Department of Mechanical Engineering, University of California, Berkeley, CA, 3. Computational Solid Mechanics Laboratory, University of California, Berkeley, CA, 4. Department of Bioengineering, University of California, Berkeley, CA
Abstract
Despite the importance of multiaxial failure of trabecular bone in many biomechanical applications, to date no complete multiaxial failure criterion for human trabecular bone has been developed. By using experimentally validated nonlinear high-resolution, micro-mechanical finite-element models as a surrogate for multiaxial loading experiments, we determined the three-dimensional normal strain yield surface and all combinations of the two-dimensional normal-shear strain yield envelope. High-resolution finite-element models of three human femoral neck trabecular bone specimens obtained through micro-computed tomography were used. In total, 889 multiaxial-loading cases were analyzed, requiring over 41,000 CPU hours on parallel supercomputers. Our results indicated that the multiaxial yield behavior of trabecular bone in strain space was homogeneous across the specimens and nearly isotropic. Analysis of stress-strain curves along each axis in the 3-D normal strain space indicated uncoupled yield behavior, whereas substantial coupling was seen for normal-shear loading. A modified super-ellipsoid surface with only four parameters fit the normal strain yield data very well with an arithmetic error±SD less than −0.04±5.1%. Furthermore, the principal strains associated with normal-shear loading showed excellent agreement with the yield surface obtained for normal strain loading (arithmetic error±SD<2.5±6.5%). We conclude that the four-parameter “Modified Super-Ellipsoid” yield surface presented here describes the multiaxial failure behavior of human femoral neck trabecular bone very well.
Publisher
ASME International
Subject
Physiology (medical),Biomedical Engineering
Reference38 articles.
1. Lotz, J. C., Cheal, E. J., and Hayes, W. C., 1991, “Fracture prediction for the proximal femur using finite-element models: Part I-Linear analysis,” J. Biomech. Eng., 113, pp. 353–360. 2. Lotz, J. C., Cheal, E. J., and Hayes, W. C., 1991, “Fracture prediction for the proximal femur using finite-element models: Part II-Nonlinear analysis,” J. Biomech. Eng., 113, pp. 361–365. 3. Cheal, E. J., Hayes, W. C., Lee, C. H., Snyder, B. D., and Miller, J., 1985, “Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth,” J. Orthop. Res., 3, pp. 424–434. 4. Keyak, J. H., and Rossi, S. A., 2000, “Prediction of femoral fracture load using finite element models: an examination of stress- and strain-based failure theories,” J. Biomech., 33, pp. 209–214. 5. Cody, D. D., Gross, G. J., Hou, F. J., Spencer, H. J., Goldstein, S. A., and Fyhrie, D. P., 1999, “Femoral strength is better predicted by finite-element models than QCT and DXA,” J. Biomech., 32, pp. 1013–1020.
Cited by
83 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Peak Load Prediction of Human Bone Proximal Femur: Sensitivity to Tissues Strength and Geometry;Direct Methods for Limit State of Materials and Structures;2023 2. Bone strength, bone remodeling, and Biomechanics of fracture;Digital Human Modeling and Medicine;2023 3. Influence of bone marrow characteristic and trabecular bone morphology on bone remodelling process with FSI approach;Proceedings of the Institution of Mechanical Engineers, Part L: Journal of Materials: Design and Applications;2022-02-24 4. Bone biomechanics;Human Orthopaedic Biomechanics;2022 5. Limit analysis of human proximal femur;Journal of the Mechanical Behavior of Biomedical Materials;2021-12
|
|