Abstract With increasing aerodynamic and thermal loads, film cooling has been a popular technology integrated into the design of the modern gas turbine vane endwall, especially for the first-stage vane endwall. A staggering amount of research has been completed to quantify the effect of operating conditions and cooling hole geometrical properties. However, most of these investigations did not address the influence of the manufacturing tolerances, assembly errors, and operation degradations on the endwall misalignment. In this paper, uncertainty quantification (UQ) analysis was performed to quantify the impacts of upstream endwall misalignment uncertainties on the endwall film cooling performance and vane surface phantom cooling performance. The upstream endwall misalignment, step geometry with various step heights, commonly exists between the combustor exit and the first-stage vane endwall. Based on the non-intrusive polynomial chaos expansion (NIPC) and the uniform probability distribution assumption, the deviation (step height) uncertainties of the upstream endwall misalignment were quantified. To predict the endwall secondary flow and film cooling effectiveness in the transonic linear vane passage, the commercial computational fluid dynamic solver ANSYS FLUENT was used to numerically solve the three-dimensional steady-state Reynolds-Averaged Navier–Stokes (RANS) equations. The robustness analysis of endwall film cooling performance and phantom cooling performance to the upstream endwall misalignment was conducted for three design upstream step heights (ΔH): a baseline configuration (ΔH = 0 mm), two misaligned configurations with forward step (ΔH = −5 mm) and backward step (ΔH = 5 mm), respectively. Results show that the actual cooling performance has a high probability of deviating from the nominal value for the baseline configuration. The critical regions that are most sensitive to the upstream step misalignment are also identified by variances. The UQ results also show that the design geometry with a forward step has a more robust film cooling performance on endwall and phantom cooling performance on the vane pressure side surface, which means a smaller variance and a better expectation than the no-step configuration. In contrast, the design geometry with a backward step induces the reductions in the expectation of the film cooling effectiveness and coolant coverage and the amplification of performance fluctuations. This work provides a certain guiding direction for the optimization design for the upstream step geometry.

Funder

National Natural Science Foundation of China

Publisher

ASME International

Subject

Mechanical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3