Experiment on the Excitation of Vapor Behavior and the Vibration by Thermal Flow Under C-Tube Pool Boiling Model

Author:

Xu Ruosi12,Tan Wei12,Dong Jiaojiao3,Guo Kai4,Zhang Haiying3,Wang Heng5,Zhu Guorui12

Affiliation:

1. School of Chemical Engineering and Technology, Tianjin University , Tianjin 300350, China ; , Ningbo, Zhejiang 315000, China

2. Zhejiang Institute of Tianjin University , Tianjin 300350, China ; , Ningbo, Zhejiang 315000, China

3. China Nuclear Power Engineering Co., Ltd. , Beijing 100840, China

4. School of Environmental and Chemical Engineering, Yanshan University , Qinhuangdao, Hebei 066200, China

5. Zhejiang Institute of Tianjin University , Ningbo, Zhejiang 315000, China

Abstract

Abstract As an important safety equipment in nuclear system, the passive residual heat removal heat exchanger (PRHR HX) with C-tube is responsible for timely removing heat from the reactor core in accident. A C-tube heating device was setup to investigate the flow characteristics of the in-containment refueling water storage tank (IRWST), which is of the PRHR HX shell-side flow field and the vibration characteristics of the heat exchanger tube. The temperature of the flow field and the acceleration signal of the C-tube were measured. The C-tube frequency in the pool boiling condition is 0–0.660 Hz. There is no resonance with the first natural frequency of 8.98 Hz. The IRWST temperature field can be divided into slow-heating period, fast-heating period, and boiling period. Steam vapor exists in three periods, condensation and collapse of vapor concentrate on horizontal tube. The fast-heating period exists the subcooling degree ΔTsub for the most intense vapor excitation, ΔTsub is in the range of 13–16 °C. In term of thermal flow excitation vibration, the existence of the cross flow with C-plane direction is in the transition period from the slow-heating period to the fast-heating period, which excites the maximum root mean squares (RMS) amplitude 0.039 mm and 0.034 mm at the midpoint of upper horizontal tube and vertical tube. When the fluid enters fast-heating period, the direction of flow changes into the normal C-plane. Normal RMS amplitude reached maximum 0.02 mm at upper 1/4 of the vertical tube in boiling period. The above research provides important data support for the safety and reliability of PRHR HX.

Publisher

ASME International

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3