A Normative Database of Hip and Knee Joint Biomechanics During Dynamic Tasks Using Four Functional Methods With Three Functional Calibration Tasks

Author:

Bennett Hunter J.1,Valenzuela Kevin A.2,Fleenor Kristina1,Weinhandl Joshua T.3

Affiliation:

1. Department of Human Movement Sciences, Old Dominion University, 2016 Student Recreation Center, Norfolk, VA 23529

2. Department of Kinesiology, HHS2-203, California State University Long Beach, Long Beach, CA 90840

3. Department of Kinesiology, Recreation, and Sport Studies, The University of Tennessee, 322 HPER Building, 1914 Andy Holt Avenue, Knoxville, TN 37996-2700

Abstract

Abstract Although predicted hip joint center (HJC) locations are known to vary widely between functional methods, no previous investigation has detailed functional method-dependent hip and knee biomechanics. The purpose of this study was to define a normative database of hip joint biomechanics during dynamic movements based upon functional HJC methods and calibration tasks. Thirty healthy young adults performed arc, star arc, and two-sided calibration tasks. Motion capture and ground reaction forces were collected during walking, running, and single-leg landings (SLLs). Two sphere-fit (geometric and algebraic) and two coordinate transformation techniques were implemented using each calibration (12 total method–calibration combinations). Surprisingly, the geometric fit-two-sided model placed the HJC at the midline of the pelvis and above the iliac spines, and thus was removed from analyses. A database of triplanar hip and knee kinematics and hip moments and powers was constructed using the mean of all subjects for the eleven method–calibration combinations. A nested analysis of variance approach compared calibration [method] peak hip kinematics and kinetics. Most method differences existed between geometric fit and coordinate transformations (58 of 84 total). No arc-star arc differences were found. Thirty-two differences were found between the two-sided and arc/star arc calibrations. This database of functional method based hip and knee biomechanics serves as an important reference point for interstudy comparisons. Overall, this study illustrates that functional HJC method can dramatically impact hip biomechanics and should be explicitly detailed in future work.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3