Changes in the Tangent Modulus of Rabbit Septal and Auricular Cartilage Following Electromechanical Reshaping

Author:

Lim Amanda1,Protsenko Dmitry E.2,Wong Brian J. F.3

Affiliation:

1. Department of Biomedical Engineering, The Beckman Laser Institute and Medical Clinic, University of California, Irvine, Irvine, CA 92697

2. The Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine, CA 92612

3. Department of Otolaryngology, Head and Neck Surgery and Department of Biomedical Engineering, The Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine, CA 92612

Abstract

Transforming decades’ old methodology, electromechanical reshaping (EMR) may someday replace traditionally destructive surgical techniques with a less invasive means of cartilage reshaping for reconstructive and esthetic facial surgery. Electromechanical reshaping is essentially accomplished through the application of voltage to a mechanically deformed cartilage specimen. While the capacity of the method for effective reshaping has been consistently shown, its associated effects on cartilage mechanical properties are not fully comprehended. To begin to explore the mechanical effect of EMR on cartilage, the tangent moduli of EMR-treated rabbit septal and auricular cartilage were calculated and compared to matched control values. Between the two main EMR parameters, voltage and application time, the former was varied from 2–8 V and the latter held constant at 2 min for septal cartilage, 3 min for auricular cartilage. Flat platinum electrodes were used to apply voltage, maintaining the flatness of the specimens for more precise mechanical testing through a uniaxial tension test of constant strain rate 0.01 mm/s. Above 2 V, both septal and auricular cartilage demonstrated a slight reduction in stiffness, quantified by the tangent modulus. A thermal effect was observed above 5 V, a newly identified EMR application threshold to avoid the dangers associated with thermoforming cartilage. Optimizing EMR application parameters and understanding various side effects bridge the gap between EMR laboratory research and clinical use, and the knowledge acquired through this mechanical study may be one additional support for that bridge.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3