Affiliation:
1. Heat Transfer Research, Inc., Alhambra, Calif. 91802
Abstract
In a study of fouling of heat exchangers, aqueous solutions of CaSO4 and Li2SO4 were circulated through electrically heated tubes at controlled conditions. Measured induction periods and fouling rates of both salts were found to be primarily functions of the supersaturation of the solutions. Secondary correlating parameters were surface temperature for the Li2SO4 solutions and mass transfer coefficients for the CaSO4 solutions.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
45 articles.