Computational Fluid Dynamics Turbulence Model and Experimental Study for a Fontan Cavopulmonary Assist Device

Author:

Sarfare Shreyas1,Ali MD Shujan1,Palazzolo Alan1,Rodefeld Mark2,Conover Tim3,Figliola Richard4,Giridharan Guruprasad5,Wampler Richard6,Bennett Edward7,Ivashchenko Artem7

Affiliation:

1. Department of Mechanical Engineering, Texas A&M University , College Station, TX 77843

2. Section of Cardiothoracic Surgery, Department of Surgery, Indiana University School of Medicine , Indianapolis, IN 46202

3. Department of Mechanical & Bioengineering, Clemson University , Clemson, SC 29634

4. Department of Mechanical & Bioengineering, Clemson University , Clemson, SC 29634-0921

5. Department of Bioengineering, University of Louisville , Louisville, KY 40292

6. Oregon Heart Center , Salem, OR 97301

7. Mechanical Solutions, Inc. , 11 Apollo Drive, Whippany, NJ 07981

Abstract

Abstract Head-flow HQ curves for a Fontan cavopulmonary assist device (CPAD) were measured using a blood surrogate in a mock circulatory loop and simulated with various computational fluid dynamics (CFD) models. The tests benchmarked the CFD tools for further enhancement of the CPAD design. Recommended Reynolds-Averaged Navier–Stokes (RANS) CFD approaches for the development of conventional ventricular assist devices (VAD) were found to have shortcomings when applied to the Fontan CPAD, which is designed to neutralize off-condition obstruction risks that could contribute to a major adverse event. The no-obstruction condition is achieved with a von Karman pump, utilizing large clearances and small blade heights, which challenge conventional VAD RANS-based CFD hemodynamic simulations. High-fidelity large eddy simulation (LES) is always recommended; however, this may be cost-inhibitive for optimization studies in commercial settings, thus the reliance on RANS models. This study compares head and power predictions of various RANS turbulence models, employing experimental measurements and LES results as a basis for comparison. The models include standard k−ϵ, re-normalization group k−ϵ, realizable k−ϵ, shear stress transport (SST) k−ω, SST with transitional turbulence, and Generalized k−ω. For the pressure head predictions, it was observed that the standard k−ϵ model provided far better agreement with experiment. For the rotor torque, k−ϵ predictions were 30% lower than LES, while the SST and LES torque values were near identical. For the Fontan CPAD, the findings support using LES for the final design simulations, k−ϵ model for head and general flow simulation, and SST for power, shear stress, hemolysis, and thrombogenicity predictions.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference41 articles.

1. Surgical Repair of Tricuspid Atresia;Thorax,1971

2. Cavopulmonary Assist: Circulatory Support for the Univentricular Fontan Circulation;Ann. Thorac. Surg.,2003

3. Flow Field Instability and Rotordynamic Impedances for an Open Impeller Centrifugal Pump in Transient Four-Quadrant Regimes,2020

4. System Level Analysis of Compressor Eye-Labyrinth Seal Rotordynamic Forces: A Computational Fluid Dynamics Approach,2021

5. Parametric Study of Two-Phase Flow in a Porous Wick of a Mechanically Pumped Loop Heat Pipe;AIP Conf. Proc.,,2021

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献