Affiliation:
1. Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa 32000, Israel
Abstract
Most of the myriad (order of 109) interconnected coronary vessels interact nonlinearly with their embedding contracting myocardium. Their dynamic flow can be simulated based on a nonlinear distributive segmental flow model involving highly nonlinear partial differential equations. Such network flow analysis, although of high accuracy, is computationally excessively complex. On the other hand, a corresponding nonlinear lumped analysis is significantly less demanding since it involves ordinary differential equations. This is, however, at the detriment of accuracy. In the present technical report, a nonlinear lumped representation of coronary segmental flow is presented and tested against predictions of the corresponding distributive analysis. The results suggest that under physiological conditions, the proposed lumped model achieves similar accuracy to the distributive one, yet with considerably higher computational speed.
Subject
Physiology (medical),Biomedical Engineering
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献