Effect of Spanwise Hole-to-Hole Spacing on Overall Cooling Effectiveness of Effusion Cooled Combustor Liners for a Swirl-Stabilized Can Combustor

Author:

Ahmed Shoaib1,Wahls Benjamin H.2,Ekkad Srinath V.3,Lee Hanjie4,Ho Yin-Hsiang5

Affiliation:

1. North Carolina State University Mechanical and Aerospace Engineering, , 911 Oval Drive, Engineering Building III, Room 3002, Raleigh, NC 27695

2. North Carolina State University Mechanical and Aerospace Engineering, , 1840 Entrepreneur Drive, Room 3002, EB3, Raleigh, NC 27695

3. North Carolina State University Mechanical and Aerospace Engineering, , 911 Oval Drive, 3002 EB III, Raleigh, NC 27695

4. Solar Turbines Inc. , 2200 Pacific Highway, P. O. Box 85376, Combustion Engineering, San Diego, CA 85376

5. Solar Turbines Inc. , 2200 Pacific Highway, P. O. Box 85376, Mail Zone E-4 Combustion Engineering, San Diego, CA 85376

Abstract

Abstract One of the most effective ways to cool the combustor liner is through effusion cooling. Effusion cooling (also known as full-coverage effusion cooling) involves uniformly spaced holes distributed throughout the combustor liner wall. Effusion cooling configurations are preferred for their high effectiveness, low-pressure penalty, and ease of manufacturing. In this article, experimental results are presented for effusion cooling configurations for a realistic swirl driven can combustor under reacting (flame) conditions. The can combustor was equipped with an industrial engine swirler and gaseous fuel (methane), subjecting the liner walls to engine representative flow and combustion conditions. In this study, three different effusion cooling liners with spanwise spacings of r/d = 6, 8, and 10 and streamwise spacing of z/d = 10 were tested for four coolant-to-main airflow ratios. The experiments were carried out at a constant main flow Reynolds number (based on combustor diameter) of 12,500 at a total equivalence ratio of 0.65. Infrared thermography (IRT) was used to measure the liner outer surface temperature, and detailed overall effectiveness values were determined under steady-state conditions. The results indicate that decreasing the spanwise hole-to-hole spacing (r/d) from ten to eight increased the overall cooling effectiveness by 2–5%. It was found that reducing the spanwise hole-to-hole spacing further to r/d = 6 does not affect the cooling effectiveness implying the existence of an optimum spanwise hole-to-hole spacing. Also, the minimum liner cooling effectiveness on the liner wall was found to be downstream of the impingement location, which is not observed in the existing literature for experiments done under nonreacting conditions.

Publisher

ASME International

Subject

Mechanical Engineering

Reference26 articles.

1. Comparison of Advanced Cooling Concepts Using Color Thermography;Myers,1985

2. A Review of Gas Turbine Effusion Cooling Studies;Krewinkel;Int. J. Heat Mass Transfer,2013

3. Full Coverage Effusion Film Cooling With Inclined Holes;Andrews,1995

4. Full Coverage Discrete Hole Film Cooling: The Influence of Hole Size;Andrews,1985

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3