Affiliation:
1. University of Leeds, Leeds, UK
Abstract
The influence of hole size and hence blowing rate on full coverage discrete hole wall cooling for gas turbine combustion chamber applications was investigated. Two temperature conditions were used firstly a 750K gas temperature and 300K coolant, and secondly a realistic combustor primary zone conditions of 2100K flame temperature and 700K coolant. It was shown that a large hole size resulted in a significant improvement in the overall cooling effectiveness due to a reduced film heat transfer coefficient. At high temperature the cooling effectiveness was reduced due to radiative heat transfer from the flame gases. At low coolant flow large temperature increases of the coolant occurred within the wall and approached the transpiration situation.
Publisher
American Society of Mechanical Engineers
Cited by
9 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献