A Musculoskeletal Model of the Equine Forelimb for Determining Surface Stresses and Strains in the Humerus—Part I. Mathematical Modeling

Author:

Pollock Sarah1,Hull M. L.2,Stover Susan M.3,Galuppo Larry D.4

Affiliation:

1. Biomedical Engineering Program, University of California, One Shields Avenue, Davis, CA 95616

2. Department of Mechanical Engineering, and Biomedical Engineering Program, University of California, One Shields Avenue, Davis, CA 95616

3. Department of Anatomy, Physiology and Cell Biology, School of Veterinary Medicine, and Biomedical Engineering Program, University of California, One Shields Avenue, Davis, CA 95616

4. Department of Anatomy, Physiology, and Cell Biology, School of Veterinary Medicine, University of California, One Shields Avenue, Davis, CA 95616

Abstract

Knowledge of the forces that act upon the equine humerus while the horse is standing and the resulting strains experienced by the bone is useful for the prevention and treatment of fractures and for assessing the proximolateral aspect of the bone as a site for obtaining autogenous bone graft material. The first objective was to develop a mathematical model to predict the loads on the proximal half of the humerus created by the surrounding musculature and ground reaction forces while the horse is standing. The second objective was to calculate surface bone stresses and strains at three cross sections on the humerus corresponding to the donor site for bone grafts, a site predisposed to stress fracture, and the middle of the diaphysis. A three-dimensional mathematical model employing optimization techniques and asymmetrical beam analysis was used to calculate shoulder muscle forces and surface strains on the proximal and mid-diaphyseal aspects of the humerus. The active shoulder muscles, which included the supraspinatus, infraspinatus, subscapularis, and short head of the deltoid, produced small forces while the horse is standing; all of which were limited to 4.3% of their corresponding maximum voluntary contraction. As a result, the strains calculated at the proximal cross sections of the humerus were small, with maximum compressive strains of −104με at the cranial aspect of the bone graft donor cross section. The middle of the diaphysis experienced larger strain magnitudes with compressive strains at the lateral and the caudal aspects and tensile strains at the medial and cranial aspects (−377με and 258με maximum values, respectively) while the horse is standing. Small strains at the donor bone graft site do not rule out using this location to harvest bone graft tissue, although strains while rising to a standing position during recovery from anesthesia are unknown. At the site common to stress fractures, small strains imply that the stresses seen by this region while the horse is standing, although applied for long periods of time, are not a cause of fracture in this location. Knowing the specific regions of the middle of the diaphysis of the humerus that experience tensile and compressive strains is valuable in determining optimum placement of internal fixation devices for the treatment of complete fractures.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3