Abstract

Accurate force simulation is essential to haptic simulators for surgical training. Factors such as tissue inhomogeneity pose unique challenges for simulating needle forces. To aid in the development of haptic needle insertion simulators, a handheld force sensing syringe was created to measure the motion and forces of needle insertions. Five needle insertions were performed into the neck of a cadaver using the force sensing syringe. Based on these measurements a piecewise exponential needle force characterization, was implemented into a haptic central venous catheterization (CVC) simulator. The haptic simulator was evaluated through a survey of expert surgeons, fellows, and residents. The maximum needle insertion forces measured ranged from 2.02 N to 1.20 N. With this information, four characterizations were created representing average, muscular, obese, and thin patients. The median survey results showed that users statistically agreed that “the robotic system made me sensitive to how patient anatomy impacts the force required to advance needles in the human body.” The force sensing syringe captured force and position information. The information gained from this syringe was able to be implemented into a haptic simulator for CVC insertions, showing its utility. Survey results showed that experts, fellows, and residents had an overall positive outlook on the haptic simulator's ability to teach haptic skills.

Funder

"National Heart, Lung, and Blood Institute"

Publisher

ASME International

Subject

Biomedical Engineering,Medicine (miscellaneous)

Reference15 articles.

1. The Role of Medical Simulation: An Overview;Int. J. Med. Rob. Comput. Assisted Surg.,2006

2. The Role of Haptics in Medical Training Simulators: A Survey of the State of the Art;IEEE Trans. Haptics,2011

3. Construct Validity for the LAPSIM Laparoscopic Surgical Simulator;Surg. Endoscopy Other Interventional Tech.,2005

4. Integrating Haptics With Augmented Reality in a Femoral Palpation and Needle Insertion Training Simulation;IEEE Trans. Haptics,2011

5. Roth Monzon, E. L., Dumas, C., Chellah, A., and Cao, C. G. L., 2011, “Haptic Sensitivity in Needle Insertion: The Effects of Training and Visual Aid,” International Skills Conference, Montpellier, France, Dec. 15–16, pp. 250–253.

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3