Design of a Free-Floating Polycarbonate-Urethane Meniscal Implant Using Finite Element Modeling and Experimental Validation

Author:

Elsner Jonathan J.1,Portnoy Sigal1,Zur Gal1,Guilak Farshid2,Shterling Avi1,Linder-Ganz Eran1

Affiliation:

1. Research and Development Center, Active Implants Corporation, Netanya 42505, Israel

2. Duke University Medical Center, Durham, NC 27710

Abstract

The development of a synthetic meniscal implant that does not require surgical attachment but still provides the biomechanical function necessary for joint preservation would have important advantages. We present a computational-experimental approach for the design optimization of a free-floating polycarbonate-urethane (PCU) meniscal implant. Validated 3D finite element (FE) models of the knee and PCU-based implant were analyzed under physiological loads. The model was validated by comparing calculated pressures, determined from FE analysis to tibial plateau contact pressures measured in a cadaveric knee in vitro. Several models of the implant, some including embedded reinforcement fibers, were tested. An optimal implant configuration was then selected based on the ability to restore pressure distribution in the knee, manufacturability, and long-term safety. The optimal implant design entailed a PCU meniscus embedded with circumferential reinforcement made of polyethylene fibers. This selected design can be manufactured in various sizes, without risking its integrity under joint loads. Importantly, it produces an optimal pressure distribution, similar in shape and values to that of natural meniscus. We have shown that a fiber-reinforced, free-floating PCU meniscal implant can redistribute joint loads in a similar pattern to natural meniscus, without risking the integrity of the implant materials.

Publisher

ASME International

Subject

Physiology (medical),Biomedical Engineering

Reference42 articles.

1. In-Vitro Measurement of Static Pressure Distribution in Synovial Joints—Part I: Tibial Surface of the Knee;Ahmed;ASME J. Biomech. Eng.

2. Load-Bearing Mode of the Knee Joint: Physical Behavior of the Knee Joint With or Without Menisci;Kurosawa;Clin. Orthop. Relat. Res.

3. The Effect of Lateral Meniscectomy on Motion of the Knee;Levy;J. Bone Jt. Surg., Am. Vol.

4. Late Degenerative Changes After Meniscectomy. Factors Affecting the Knee After Operation;Allen;J. Bone Jt. Surg., Br. Vol.

5. Risk Factors for Symptomatic Knee Osteoarthritis Fifteen to Twenty-Two Years After Meniscectomy;Englund;Arthritis Rheum.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3