Affiliation:
1. Technische Universität Berlin, Berlin, Germany
Abstract
Wind turbine industry has a special need for accurate post stall airfoil data. While literature often covers incidence ranges [−10deg,+25deg] smaller machines experience a range of up to 90 deg for horizontal axis and up to 360 deg for vertical axis wind turbines (VAWTs). The post stall data of airfoils is crucial to improve the prediction of the start-up behavior as well as the performance at low tip speed ratios. The present paper analyzes and discusses the performance of the symmetrical NACA 0021 airfoil at three Reynolds numbers (Re = 100k, 140k, and 180k) through 180 deg incidence. The typical problem of blockage within a wind tunnel was avoided using an open test section. The experiments were conducted in terms of surface pressure distribution over the airfoil for a tripped and a baseline configuration. The pressure was used to gain lift, pressure drag, moment data. Further investigations with positive and negative pitching revealed a second hysteresis loop in the deep post stall region resulting in a difference of 0.2 in moment coefficient and 0.5 in lift.
Publisher
American Society of Mechanical Engineers
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献