Affiliation:
1. Department of Mechanical Engineering, University of Colorado, Boulder, Colo. 80309
Abstract
The paper reports an experimental study of natural convection between two water reservoirs connected through a two-dimensional horizontal duct. The flow field was visualized and the velocities were measured using the thymol blue pH indicator method. The temperature field in the duct region and the heat transfer rate through the duct were also measured. It is shown that the duct flow consists of two streams in counterflow, the warmer stream occupying the upper half of the channel. The two streams are insulated from one another by a mid-depth buffer layer. The measurements demonstrate that the heat transfer mechanism differs fundamentally from the mechanism envisioned in the Bejan and Tien theory [6]. It is also suggested that the basic design of the experimental apparatus can be used in future studies of stability of shear flows in stratified fluids.
Subject
Mechanical Engineering,Mechanics of Materials,Condensed Matter Physics,General Materials Science
Cited by
24 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献