Cost-Effectiveness and Resiliency Evaluation of Net-Zero Energy U.S. Residential Communities

Author:

Thompson Jordan1,Krarti Moncef1

Affiliation:

1. Department of Civil, Environmental, and Architectural Engineering, University of Colorado, 1111 Engineering Dr., Boulder, CO 80309

Abstract

Abstract In this paper, a resiliency analysis is carried out to assess the energy, economic, and power outage survivability benefits of efficient and net-zero energy communities. The analysis addresses the appropriate steps to designing an energy-efficient and net-zero energy community using Phoenix, Arizona, as a primary location for weather and utility inputs. A baseline home is established using International Energy Conservation Code (IECC) 2018 code requirements. Three occupancy levels are evaluated in BEopt to provide diversity in the community’s building stock. The loads from the baseline, energy-efficient optimum, and net-zero energy optimum single-family homes are utilized to determine energy use profiles for various residential community types using occupancy statistics for Phoenix. Then, REopt is used to determine the photovoltaic (PV) and battery storage system sizes necessary for the community to survive a 72-hour power outage. The analysis results indicated that the baseline community requires a 544-kW PV system and 375-kW/1,564 kWh battery storage system to keep all electrical loads online during a 72-hour power outage. The energy-efficient community requires a 291-kW PV system and a 202-kW/820 kWh battery storage system while the net-zero energy community requires a 291-kW PV system and a 191-kW/880 kWh battery storage system. In this study, the economic analysis indicates that it is 31% more cost-effective to install a shared PV plus storage system than to install individual PV plus storage systems in an energy-efficient community. After analyzing the system sizes and costs required to survive various outage durations, it is found that only a 4% difference in net present cost exists between a system sized for a 24-hour outage and a 144-hour outage. In the event of a pandemic or an event that causes a community-wide lockdown, the energy-efficient community would only survive 6 h out of a 72-hour power outage during a time where plug loads are increased by 50% due to added laptops, monitors, and other office electronics. Finally, a climate sensitivity analysis is conducted for efficient communities in Naperville, Illinois, and Augusta, Maine. The analysis suggests that for a 72-hour power outage starting on the peak demand day and time of the year, the cost of resiliency is higher in climates with more heating and cooling needs as heating, ventilation, air conditioning, and cooling (HVAC) is consistently the largest load in a residential building.

Publisher

ASME International

Reference44 articles.

1. NZEB;European Commission,2019

2. Zero Net Energy;California Public Utilities Commission,2020

3. Think Bigger: Net-Zero Communities;Kallushi,2012

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370