Affiliation:
1. Westinghouse Fluid Systems Laboratory, West Lafayette, Ind. 47906
Abstract
This paper describes a systematic study of the influence of the inlet clearance gap on the performance of a centrifugal fan. Overall fan performance in terms of volume flow rate, pressure rise, stall margin, and efficiency were measured over a range of values of the radial clearance between the impeller and the stationary inlet cone. These data have been correlated as functions of lumped clearance parameters. Additional data on velocity surveys in the impeller discharge are presented and discussed in relation to overall performance.
Subject
Mechanical Engineering,Energy Engineering and Power Technology,Aerospace Engineering,Fuel Technology,Nuclear Energy and Engineering
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献