Affiliation:
1. Department of Mechanical Engineering, University of Kansas, Lawrence, KS 66045
Abstract
Abstract
This investigation into phase change material (PCM)-based passive thermal management systems was conducted via an experimental approach using 19.5 A h lithium iron phosphate cells with dimensions of (7.25 × 160 × 227) mm3. Trials were conducted at currents from 1 to 5C and environmental temperatures from 4 to 35 °C to simulate applications at which a Li-ion battery would be expected to perform. Based on comparisons, including an air-only control, the system consisting of PCM combined with five pores per inch (PPI) aluminum foam is the most effective at regulating average battery temperature and temperature gradient. During a 3C discharge trial at room temperature, the PCM-Al foam (5 PPI) system kept the average battery temperature and the maximum temperature difference below 28.1 and 5.2 °C, respectively, compared to the air-only control system which reached values of 48.0 and 17.2 °C, respectively. When analyzing data from trials at 4 and 35 °C, similar results are found with the PCM-Al foam systems being effective at thermal management. Thus, when compared to other systems, preliminary results show great promise in the future for the use of an PCM-Al foam passive thermal management system to effectively regulate the temperature of Li-ion batteries during use.
Funder
University of Kansas
NASA EPSCoR
University of Kansas Center
Subject
Mechanical Engineering,Mechanics of Materials,Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electronic, Optical and Magnetic Materials
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献