Calibration and Tests of Commercial Wireless Infrared Thermometers

Author:

Colaizzi Paul D.,O’Shaughnessy Susan A.,Evett Steven R.

Abstract

Abstract. Applications of infrared thermometers (IRTs) in large agricultural fields require wireless data transmission, and IRT target temperature should have minimal sensitivity to internal detector temperature. To meet these objectives, a prototype wireless IRT system was developed at USDA Agricultural Research Service, Bushland, Texas, and commercialized by Dynamax, Inc., Houston, Texas. The objective of this article was to calibrate and test the Dynamax, Inc. system. Following deployment in an irrigated field during the 2015 crop season, 26 IRTs were calibrated and tested in a temperature-controlled room. The IRTs measured a black body target temperature controlled at 15°C to 55°C in 5°C increments, and for each range of black body temperatures, ambient room temperatures were controlled at 15°C, 20°C, 25°C, 35°C, and 45°C under isothermal and steady-state conditions. Discrepancies between uncalibrated IRT and black body temperatures varied by IRT and had root mean squared errors (RMSE) between 0.25°C and 1.51°C, mean absolute errors (MAE) between 0.19°C and 1.17°C, and mean bias errors (MBE) between -0.66°C and 0.16°C. A calibration equation was derived from the longwave radiation energy balance of the IRT internal detector, and sensor-specific calibrations reduced discrepancies for all IRTs, with RMSE between 0.16°C and 0.28°C, MAE between 0.12°C and 0.21°C, and absolute MBE less than 0.05°C. A generic calibration was derived by pooling all sensor-specific calibrations, and reduced discrepancies for all but five IRTs, but these were very marginal compared with no calibration. Therefore, the generic calibration did not appear justified, but sensor-specific calibrations were justified for most IRTs. The IRTs were again deployed in the irrigated field and measured corn canopy temperature in 2016. Crop evapotranspiration (ETc) was calculated using measurements from one IRT and compared to ETc measured by a large weighing lysimeter. The choice of calibration (none, generic, or sensor-specific) had little impact on calculated ETc, which was likely related to a limited range of target and sensor body temperature differences in the field (mostly +10°C), in contrast to those in the temperature-controlled room (up to +40°C) Keywords: Canopy temperature, Crop management, Evapotranspiration, Irrigation, Remote sensing, Sensors.

Funder

USDA-ARS Ogallala Aquifer Program

Publisher

American Society of Agricultural and Biological Engineers (ASABE)

Subject

General Engineering

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3