A Subsurface Drip Irrigation System for Weighing Lysimetry

Author:

Evett Steven R.,Marek Gary W.,Colaizzi Paul D.,Ruthardt Brice B.,Copeland Karen S.

Abstract

Abstract. Large, precision weighing lysimeters can have accuracies as good as 0.04 mm equivalent depth of water, adequate for hourly and even half-hourly determinations of evapotranspiration (ET) rate from crops. Such data are important for testing and improving simulation models of the complex interactions of surface water and energy balances, soil physics, plant growth, and biophysics that determine crop ET in response to rapid microclimate dynamics. When crops are irrigated with sprinkler systems or other rapid additions of water, the irrigation event is typically short enough that not much ET data are compromised by the lysimeter mass change due to irrigation. In contrast, subsurface drip irrigation (SDI) systems may take many hours to apply an irrigation, during which time the lysimeter mass change is affected by both ET rate and irrigation application rate. Given that irrigation application rate can be affected by pressure dynamics of the irrigation system, emitter clogging and water viscosity changes with temperature over several-hour periods, it can be difficult to impossible to separate the ET signal from the interference of the irrigation application. The inaccuracies in the data can be important, particularly for comparisons of sprinkler and SDI systems, since they are of the order of 8 to 10% of daily ET. We developed an SDI irrigation system to apply irrigations of up to 50 mm to large weighing lysimeters while limiting the period of lysimeter mass change due to irrigation delivery to approximately ten minutes by storing the water needed for irrigation in tanks suspended from the lysimeter weighing system. The system applied water at the same rate as the SDI system in the surrounding field, allowed irrigation over periods of any duration, but often exceeding 12 h, without directly affecting lysimeter mass change and the accuracy of ET rate determinations, and allowed irrigation overnight without compromising lysimeter daily ET measurements. Errors in lysimeter ET measurements using the previous SDI system, which was directly connected to the field irrigation system, were up to 10% of daily ET compared with negligible error using the new system. Errors using the previous, directly connected, SDI system varied over time due to variable system pressure, and possibly due to water temperature (viscosity) changes and emitter clogging. With the new system, all of the water transferred to the lysimeter weighing system was eventually applied by the SDI system regardless of temperature, pressure, or emitter clogging. Differences between planned and applied irrigation depth were less than 2% over the irrigation season. Keywords: Evapotranspiration, ET, Subsurface drip irrigation, SDI, Weighing lysimeter.

Publisher

American Society of Agricultural and Biological Engineers (ASABE)

Subject

General Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3