Actuating Force Required for Operating Various Controls of a Walk-Behind Type Paddy Transplanter Leading to Development of a Remotely Operated System

Author:

Lohan Shiv Kumar,Narang Mahesh Kumar,Singh Manjeet,Khadatkar Abhijit,Karkee Manoj

Abstract

HighlightsThe actuating force, torque, and application rate needed to operate the control levers of a walk-behind type paddy transplanter were determined.The results will be beneficial for the development of a remote-control or autonomous system for the transplanter.Such a system will reduce operator fatigue, resulting in increased work efficiency and safety.Abstract. An enormous amount of human fatigue is involved in operating the walk-behind type paddy transplanters widely used in South Asian countries, especially India. To operate a transplanter remotely, accurate estimation of the actuating force needed to operate the control levers (push/pull type), the stroke length of the levers, and the frequency of use of the levers is required so that the mechanical levers can be replaced with appropriate electronic sensors, control units, and actuators. In this study, the actuating forces and required torques of the control levers of a walk-behind type paddy transplanter (Kubota NSP-4W, model MZ175-B-1) were measured using three load-measuring instruments. The results revealed that about 24.1 N of force was required to control the accelerator lever, while the left and right steering levers required an actuating force of 24.0 N each. To start the transplanting mechanism, a much higher actuating force (78.1 N) and torque (15.47 N-m) were required 54 times per hour for the planting clutch lever; however, to stop the mechanism, a comparatively smaller force (28.3 N) and torque (5.71 N-m) were required 54 times per hour. Movement of the transplanter was controlled with the shift clutch lever, which required 14.30 N of force and 2.72 N-m torque for forward movement of the transplanter in field conditions, while 12.7 N of force and 2.88 N-m torque were required for forward movement of the transplanter on paved roads. These findings will be beneficial for selecting the force and stroke length of actuators for the development of a remote-control or autonomous system for walk-behind type paddy transplanters and similar machines, which is expected to substantially reduce the operator workload and enhance both workability and safety. Keywords: Actuating force, Hand control levers, Remotely controlled paddy transplanter.

Publisher

American Society of Agricultural and Biological Engineers (ASABE)

Subject

Public Health, Environmental and Occupational Health,General Agricultural and Biological Sciences,Safety, Risk, Reliability and Quality

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3