Design and Performance of an Experimental Cooled Perch System for Heat Stress Relief of Laying Hens

Author:

Xiong Yijie,Gates Richard S.,Hu Jiaying,Hester Patricia Y.,Cheng Heng-wei

Abstract

This article summarizes the design and performance of a cooled perch system for laying hens during heat stress.Water flow rates, perch loop water temperatures, and system net heat gain are provided.The average daily net heat absorption data, useful for sizing thermal water storage and chiller capacity in future applications, is 256 W m-1 perch length, or 43.2 W per hen housed.This analysis provides a baseline for future cooled perch system design in other application settings.Abstract. This article summarizes the engineering design and performance of a cooled perch system used in a multi-year collaborative study to evaluate cooled perch effects on hen production, health, and welfare during heat stress. The cooled perch system consisted of two replicates (CP-1 and CP-2) of three-tier cage units with galvanized perch pipes forming a complete loop in each tier (top, middle, bottom) in which chilled water circulated. A total of 324 White Leghorns at 17 weeks of age were randomly assigned to 36 cages (76 cm × 52 cm × 48 cm) in six banks placed in the same room. Flow for each loop was provided by loop pumps that drew chilled water from an open thermal storage manifold and returned it to the same manifold. Each thermal storage was cooled by continuously circulating water through a water chiller. Each loop pump was thermostatically controlled based on the cage air temperature. The water inlet and outlet temperatures, cage air temperatures, and loop water flow rates during stable system operation were measured for performance evaluation. Mean water flow rates in 2015 were 5.19 and 5.45 kg min-1 for CP-1 and CP-2, respectively, but significantly declined to 3.91 and 4.03 kg min-1 in 2016. The mean loop water temperature rise was about 2°C for both replicates. The mean loop net heat gain of CP-1 and CP-2 ranged from 690 to 850 W and from 551 to 1,298 W, respectively, with a significant difference between CP-2 loops (p < 0.0001), indicating a discrepancy between the manufacturer’s pump curve and field performance. There was a correlation between room air temperature and net heat gain for all loops of CP-1 and the top loop of CP-2 (p < 0.0001), suggesting that natural convection and radiation from the room to the pipe were the major contributors to loop heat gain. The average daily net heat gain was approximately 2,334 W per replicate, 256 W m-1 perch length, or 43.2 W per hen housed. This analysis provides a baseline for future cooled perch system design in other application settings. An example is provided for sizing the thermal water storage and chiller capacity. In addition, a closed water system with a properly sized expansion tank is recommended for future energy-efficient cooled perch applications. Keywords: Alternative cooling, Heat stress, Heat transfer, Poultry.

Funder

USDA-NIFA Competitive Grants Program

Publisher

American Society of Agricultural and Biological Engineers (ASABE)

Subject

Soil Science,Agronomy and Crop Science,Biomedical Engineering,Food Science,Forestry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3