Abstract

This lecture describes the latest findings with respect to the long-term performance of modern municipal solid waste (MSW) landfill barrier systems. Field data relating to the clogging of leachate collection systems and the latest techniques for predicting their performance are examined. It is indicated that the primary leachate collection systems may have service lives that range from less than a decade to more than a century, depending on the design details, waste characteristics and mode of operation. Recent data indicate that landfill liner temperatures can be expected to reach at least 30–40°C for normal landfill operations. With recirculation of leachate the liner temperature increases faster than under normal operating conditions, and may be expected to exceed 40°C. Temperatures (up to 40–60°C) may occur at the base of landfills where there is a significant leachate mound. Temperature is shown to have a significant impact on both contaminant migration and the service life of the liner system. Field measurements and theoretical calculations show that composite liners are substantially better than single liners in terms of controlling leakage from landfills. Also, the leakage rates with a composite liner are very small, and diffusion will dominate as a transport mechanism for contaminants that can readily diffuse through a geomembrane (GM). Composite liners involving a GM over a geosynthetic clay liner (GCL) gave rise to substantially less leakage than those involving a compacted clay liner (CCL). The observed leakage through composite liners can be explained by the holes in, or adjacent to, wrinkles/waves in the GM, and this leakage can be calculated using simple equations. High-density polyethylene (HDPE) GMs provide an excellent diffusive barrier to ions. However, some organic compounds readily diffuse through HDPE GMs, and a combination of GM and an adequate thickness of liner and attenuation layer are required to control impact to negligible levels. The long-term performance of HDPE GMs is discussed. Based on the currently available data, the service life for HDPE GM in MSW landfill is estimated to be about 160 years for a primary liner at 35°C and greater than 600 years for a secondary GM provided it is at a temperature of less than 20°C. Clay liners are susceptible to both shrinkage and cracking during construction (due to heating by solar radiation or freezing) and after placement of the waste (due to temperature gradients generated by the waste). The former can be controlled by quickly covering the liner with a suitable protection layer. The latter can be controlled by appropriate design. The use of numerical models for predicting the service lives of engineered systems and long-term contaminant transport is demonstrated.

Publisher

Thomas Telford Ltd.

Subject

Earth and Planetary Sciences (miscellaneous),Geotechnical Engineering and Engineering Geology

Reference157 articles.

1. Armstrong M. D. Laboratory program to study clogging in a leachate collection system. MESc thesis, 1998, University of Western Ontario, London, Ontario, Canada.

Cited by 514 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3