Compressive loading of structural insulated panels and conventional stud walls: a study

Author:

Abbasi Hassan1ORCID,Hojatkashani Ata2ORCID,Sennah Khaled3ORCID,Nematianjelodar Hossein4ORCID

Affiliation:

1. Assistant Professor, Department of Civil Engineering, Islamic Azad University, South Tehran Branch, Tehran, Iran (corresponding author: )

2. Assistant Professor, Department of Civil Engineering, Islamic Azad University, South Tehran Branch, Tehran, Iran

3. Professor, Civil & Environmental Engineering Department, Ryerson University, Toronto, Canada

4. PhD Candidate, Department of Civil Engineering, Islamic Azad University, South Tehran Branch, Tehran, Iran

Abstract

Structural insulated panels (SIPs) are structural elements comprising a core of expanded polystyrene insulation sandwiched between two oriented strand boards. They can replace conventional joist floors and stud walls in low-rise residential construction. Three identical samples of full-scale SIP walls and stud walls were tested according to ASTM standards and experimental results for the specimens were obtained in terms of their ultimate load capacity and failure mechanism. Comparison of the load–deformation diagrams of the SIPs and stud walls showed that tangential stiffness variation of the former occurred in the hardening mode, whereas the variation for the latter was in two stages, hardening and softening. Regarding compressive loading, the results showed that SIPs are as good as conventional wood framing of the same size. Therefore, SIP walls are very efficient in the case of axial compressive loading.

Publisher

Thomas Telford Ltd.

Subject

Building and Construction,Civil and Structural Engineering

Reference19 articles.

1. Abbasi H (2014) Structural Behaviour of Insulated Foam-Timber Panels Under Gravity and Lateral Loading. PhD dissertation, Ryerson University, Toronto, ON, Canada.

2. Structural behavior of axially loaded precast foamed concrete sandwich panels

3. Design innovation, efficiency and applications of structural insulated panels: A review

4. APA (2013) ANSI/APA PRS 610.1: The standard for performance-rated structural insulated panels in wall applications. APA, Tacoma, WA, USA.

5. Experimental investigation and finite element analysis of flexural behavior of insulated concrete sandwich panels with FRP plate shear connectors

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献