Affiliation:
1. *Asahi Glass Company Ltd and †University of Surrey
Abstract
Two important parameters which control the fracture behaviour of glass fibres in cement composites, whether they contain one fibre type or are hybrids of two fibre types, are the perimeter of the glass strands in contact with hydrated cement and the way in which glass filaments fracture in multi filament strands. In scanning electron microscopy (SEM) observations, much improved images were obtained by detecting back scattered electrons rather than secondary electrons. This improvement gave good contrast between the fibre strands and the matrix, hence the perimeter of the glass strands could be determined using an image analyser. The progression of filament fracture within a strand was examined using two techniques, acid dissolution and light transmission through the filaments. These techniques showed that strands tend to fail progressively in hybrid composites containing glass and polypropylene fibres and that glass fracture continues to occur after the peak load has been reached.
Subject
General Materials Science,Building and Construction,Civil and Structural Engineering
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献