Experimental investigation of infiltration ponding in one-dimensional sand–geotextile columns

Author:

Bathurst R. J.1,Siemens G.2,Ho A. F.3

Affiliation:

1. GeoEngineering Centre at Queen's-RMC, Civil Engineering Department 13 General Crerar, Sawyer Building, Room S2414, Royal Military College of Canada, Kingston, Ontario, Canada K7K 7B4, Telephone: ext. 6479, Telefax: ,

2. GeoEngineering Centre at Queen's-RMC, Civil Engineering Department, Royal Military College of Canada Kingston, Ontario, CANADA K7K 7B4, Telephone: ext. 6396, Telefax: ,

3. Marshall Morgan & Associates Unit 301, International Plaza, 20 Sheung Yuet Road, Kowloon Bay, Hong Kong, Telephone: , Telefax: ,. Formerly: Graduate Student, GeoEngineering Centre at Queen's-RMC, Department of Civil Engineering, Queen's University, Kingston, Ontario, Canada K7L 3N6

Abstract

The paper describes the results of laboratory tests that were carried out to quantify the geotextile water characteristic curves of a woven and nonwoven geotextile in new and modified conditions. The geotextiles were modified by contamination with kaolin powder. The specimens were placed in 2 m high, one-dimensional sand columns and subjected to constant head water infiltration loading. Conductivity probes and tensiometers were used to record the unsaturated–saturated response of the sand–geotextile layers and a control column with sand only. The test results showed a detectable delay in infiltration front advancement and ponding level, which increased with decreasing saturated permeability of the geotextile specimen. The use of geotextile– water characteristic curves from in-air laboratory suction plate tests is shown to underestimate water ponding heights in the columns, which means that their use for design may be nonconservative. Another practical implication of the work reported here is that for geotextile–sand systems under surface water infiltration loading, current filtration design criteria that call for the ratio of saturated hydraulic (conductivity) permeability of the geotextile to that of the surrounding sand be at least one, may need to be strengthened. For ratios of 1 and 10, the estimated ponding height above the geotextile was estimated to be 4 and 0.1 cm, respectively. Hence, ratios of saturated hydraulic permeability greater than one may be necessary to prevent lateral flow of water above a geotextile in sand fills used in wall, slope and road applications.

Publisher

Thomas Telford Ltd.

Subject

Geotechnical Engineering and Engineering Geology,Civil and Structural Engineering

Reference43 articles.

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3