Most Patients with Abdominal Aortic Aneurysm Are Not Suitable for Endovascular Repair Using Currently Approved Bifurcated Stent-Grafts

Author:

Elkouri Stephane,Martelli Eugenio,Gloviczki Peter1,McKusick Michael A.2,Panneton Jean M.1,Andrews James C.2,Noel Audra A.,Bower Thomas C.,Sullivan Timothy M.1,Rowland Charles,Hoskin Tanya L.3,Cherry Kenneth J.1

Affiliation:

1. Rochester, MN

2. Department of Diagnostic Radiology, Mayo Clinic, Rochester, MN

3. Division of Biostatistics, Mayo Clinic, Rochester, MN

Abstract

Strict morphologic criteria must be used for patient selection to achieve durable success with endovascular aortic aneurysm repair (EVAR). The goal of this study was to assess morphologic suitability (MS) of abdominal aortic aneurysms (AAAs) for 2 currently approved bifurcated stent grafts and identify reasons for exclusion from EVAR. The authors reviewed the electronic charts of 1,795 consecutive patients who were diagnosed as having AAA between January 1999 and July 2001 at their institution. Three hundred and twenty patients had an AAA with a diameter of =5.0 cm, measured on computed tomography (CT). The records of 301 patients, 254 men, 47 women, with a mean age of 74 years were available for review, and these patients constituted the study cohort. Criteria used for MS included a proximal neck length =15 mm; neck diameter between 18 and 26 mm; neck angulation =60°; common or external iliac artery (CIA or EIA) diameters of 7–16 mm and 8–13 mm, respectively, for AneuRx (Medtronic Ave, Santa Rosa, CA) and Ancure (Guidant Cardiac and Vascular Division, Menlo Park, CA) bifurcated grafts. AAAs were suitable for AneuRx device in 14% of patients (43 of 301; 95% CI = 11–19%) and for Ancure in 5% (16 of 301; 95% CI = 3.1–9%). The main reason for exclusion was an inadequate proximal aortic neck (73%). The neck was too short in 49.5%, too wide in 64% and badly angulated in 12% of the patients. Iliac artery morphology precluded EVAR with AneuRx and Ancure devices in 52% and 80%. Both CIAs were too wide for EVAR in 43% and 77%, respectively. When iliac artery diameter =20 mm was accepted, iliac suitability for AneuRx increased from 49% to 70% and overall suitability increased from 14% to 20%. When more permissive criteria were used for MS (neck length =10 mm, neck diameter =30 mm, CIA =20), 39% of patients became candidates for EVAR. More than three fourths of the patients with an AAA =5.0 cm in size, seen in a tertiary referral center, are morphologically not suitable for EVAR using 2 currently approved bifurcated endografts. The main reasons for exclusion are a short or wide proximal aortic neck. Considerable changes in size of the devices and in proximal attachment techniques have to occur before most AAAs will be suitable for EVAR.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3