B-Mode Ultrasound Measurement of Carotid Bifurcation Stenoses: Is It Reliable?

Author:

Mackenzie Kent S.,French-Sherry Eilleen,Burns Karen,Pooley Tom1,Bassiouny Hisham S.2

Affiliation:

1. Section of Vascular Surgery, Department of Surgery, University of Chicago, Chicago, IL

2. Section of Vascular Surgery, Department of Surgery, University of Chicago, Chicago, IL;

Abstract

In the majority of cases, duplex ultrasonography (DU) is the sole imaging study necessary before carotid interventions. Duplex-derived internal carotid artery (ICA) peak systolic velocity (PSV), ICA end-diastolic velocity (EDV) and ICA/common carotid artery (CCA) PSV ratio are the most commonly utilized parameters for predicting critical carotid stenoses. However, the role of direct B-mode image measurement of maximal ICA narrowing is ill defined. The images and records of 192 patients who underwent both arteriography and duplex ultrasonography (DU) of 375 carotid arteries from January 1995 to November 2000 were reviewed. All DUs were performed by registered vascular technologists (n = 6). Maximum arteriographic stenosis was determined according to the NASCET study design. With arteriography as the “gold standard,” B-mode image (BMI) measurement of the maximal ICA luminal narrowing relative to the carotid bulb (n = 162) as well as the peak systolic velocity in the internal carotid artery (PSVICA) (n = 330), end-diastolic velocity in the internal carotid artery (EDVICA) (n = 198), and the ratio of the PSVs in both the ICA and the CCA (PSVICA/CCA) ratio (n = 319) were subjected to receiver operator characteristics (ROC) curves for 3 clinically relevant stenoses thresholds: 50-99%, 60-99%, and 70-99%. A strong correlation was found between B-mode image (BMI) and the NASCET arteriographic measures of carotid stenosis (r=0.80; p<0.001) and was similar among the 6 technologists (r=0.74-0.89; p>0.2). The overall accuracy of BMI measurement to diagnose 50%, 60%, and 70% arteriographic carotid stenosis was 85.3%, 82.2%, and 87%, respectively. BMI measurement was similar to the most accurate PSVICA, EDVICA, and PSVICA/CCA ratio at all 3 threshold stenoses levels (p>0.3). When combined with the velocity criteria, BMI measurement improved the positive predictive value (PPV) for all arteriographic stenoses thresholds by an average of 12.6% for PSVICA, 21.2% for EDVICA, and 14.2% for PSVICA/CCA ratio. BMI measurement of carotid bifurcation narrowing is as reliable as duplex-derived velocity criteria in evaluating clinically relevant threshold ICA stenoses. The routine use of B-mode ultrasound in conjunction with the velocity parameters enhances the PPV of carotid DU. Our experience suggests that with current refinements in B-mode resolution, BMI stenosis measurements are accurate among experienced technologists and are a useful adjunct to duplex-derived velocity parameters.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3