Biomechanical Characterization of an Osteoporotic Artificial Bone Model for the Distal Femur

Author:

Wähnert Dirk12,Hoffmeier Konrad L.1,Klos Kajetan1,Stolarczyk Yves1,Fröber Rosemarie3,Hofmann Gunther O.14,Mückley Thomas14

Affiliation:

1. Department of Trauma-, Hand- and Reconstructive Surgery Friedrich Schiller University Jena, Erlanger Allee 101 07747 Jena, Germany

2. AO Research Institute Davos (ARI), AO Foundation Clavadelerstr. 8, 7270 Davos, Switzerland

3. Institute of Anatomy I, Friedrich Schiller University Jena Teichgraben 7, 07743 Jena, Germany

4. Department of Trauma- and Reconstructive Surgery, BG-Kliniken Bergmannstrost Halle, Merseburger Str. 165, 06112 Halle, Germany

Abstract

The treatment of osteoporotic distal femur fractures is still an unsolved problem of trauma surgery. The poor bone stock often leads to secondary loss of reduction and implant failure. Therefore, the development of new implants and their biomechanical testing is essential. In a previous study, we developed and initially characterized an artificial osteoporotic bone model of the distal femur. This follow-up study was performed to characterize this model in a biomechanical comparison. We investigated two different artificial bones: five foam cortical shell (Sawbones) and 10 custom-made artificial femoral condyles. Additionally, eight human femora were used for comparison. For biomechanical testing, two intramedullary nails (distal femur nail (DFN) and supracondylar nail (SCN)) were cyclically axial loaded in an AO 33 C2 unstable distal femoral fracture model. In our testing, the artificial bone showed a decrease in the axial stiffness of 27% for the SCN and 28% for the DFN compared to the human results. Also the number of cycles for a deformation of 2.5 mm was reduced by 55% (SCN) and 62% (DFN). This decrease was homogenous and caused by the relative high bone mineral density of the human specimen used. The modes of failure showed no difference between the artificial and human bones. Our customized artificial bone provides suitable results. In relation to the human bones classified as mildly osteoporotic, we assume that the biomechanical properties match to serve as an osteoporotic bone. Yet, we suggest to check transferability of the results with human material.

Publisher

SAGE Publications

Subject

Biomedical Engineering,Biomaterials

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3